MI-J00
Converter Specifications
(Typical at TBP =25°C, nominal line and 75% load, unless otherwise specified)
Input Specifications
Parameter
Min
Typ
Max
Units
Test Conditions
Inrush charge
60 x10-6
100 x10-6
Coulombs
Nominal line
Input reflected
10%
IIN
Nominal line, full load
ripple current – pp
VIN
VOUT
30+20Log
(
(
)
)
dB
120Hz, nominal line
2400Hz, nominal line
Input ripple rejection
VIN
VOUT
20+20Log
dB
No load power dissipation
Output Characteristics
1.35
2
Watts
Parameter
Min
Typ
0.5
Max
1
Units
%VNOM
%VNOM
%VNOM
% / °C
Test Conditions
Setpoint accuracy
0.05
0.2
0.2
0.5
0.02
LL to HL, 10% to Full Load
LL to HL, No Load to 10%
Over rated temperature
Load/line regulation
Output temperature drift
Long term drift
0.01
0.02
100
%/1K hours
mV
150
1.5
Whichever is greater
20MHz bandwidth
Output ripple – pp
1.0
%VNOM
%VNOM
[a]
Trim range
50
110
Total remote
0.5
Volts
sense compensation
Current limit
105
105
125
130
%INOM
%INOM
Automatic restart
Short circuit current
[a] 10V to 15V outputs, standard trim range 10%. Consult factory for wider trim range.
Note: The permissible load current must never be exceeded during normal, abnormal or test conditions. For additional output related application information,
please refer to output connections on page 5.
Control Pin Specifications
Parameter
Min
Typ
50
Max
Units
Ω
Test Conditions
Gate out impedance
Gate in impedance
Gate in high threshold
Gate in low threshold
Gate in low current
1000
Ω
6
6
Volts
Volts
mA
Use open collector
0.65
MI-J00 DC-DC Converters
Page 2 of 7
Rev 1.4
06/2017
vicorpower.com
800 927.9474