Features
■ Ultra-low resistance
■ Small size
Applications
■ Battery packs
■ Alternative shapes and sizes available on
request
■ Agency recognition
■ RoHS compliant*
MF-LL Series - PTC Resettable Fuse
Electrical Characteristic
Typical
Current Trip
Limit
Initial
Resistance
Values
1 Hour (R1)
Post-Trip
Resistance
Max.
Time
To Trip
Tripped
Power
Dissipation
V max.
Volts
I max.
Amps
Model
Amperes
At 23 °C
mOhms
At 23 °C
mOhms
At 23 °C
Amperes Seconds
At 23 °C
Watts
At 23 °C
At 23 °C
Hold
1.9
Trip
4.9
Min.
5
Max.
15
Min.
5
Max.
24
Typ.
1.0
MF-LL190
6
50
9.5
2.0
Environmental Characteristics
Operating/Storage Temperature.......................-40 °C to +85 °C
Maximum Device Surface Temperature
in Tripped State ................................................+125 °C
Storage Conditions ..........................................+40 °C Max., 70 % RH Max., Packed in original packaging
Test Procedures And Requirements For Model MF-LL Series
Test
Test Conditions
Accept/Reject Criteria
Humidity Aging.................................................+60 °C, 95 % R.H., 1000 Hours...........Typical resistance change +30 % to -30 %
Passive Aging...................................................+60 °C, 1000 Hours .............................Typical resistance change +20 % to -20 %
Low temp storage ............................................-40 °C, 1000 Hours..............................Typical resistance change +5 % to -5 %
Thermal Shock .................................................+85 °C to -40 °C, 10 times...................Typical resistance change +5 % to -5 %
Vibration ...........................................................MIL-STD-883D, Method 2026 .............Rmin<R<R1 max
cUL File Number .............................................E 174545S
How to Order
Typical Time to Trip at 23 °C
MF - LL 190 __ - 0
100
Multifuse® Product
Designator
Series
LL = Low Loss
10
Hold Current, I
hold
190 (1.9 Amps)
Configuration
Blank = Standard
Packaging Option
-0 = Bulk Packaging
1
Typical Part Marking
0.1
None.
0.01
1
10
100
Fault Current (Amps)
*RoHS Directive 2002/95/EC Jan 27, 2003 including Annex.
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.