Boost Regulator with Integrated Charge Pumps,
Switch Control, and High-Current Op Amp
ELECTRICAL CHARACTERISTICS (continued)
(V
VCC
= +5V, Circuit of Figure 1, V
= V
= +13V, T = 0°C to +85°C, unless otherwise noted. Typical values are at T = +25°C.)
A
SUP A
AVDD
PARAMETER
CONDITIONS
MIN
TYP
30
MAX
60
UNITS
ꢀ
DRN-to-COM Switch On-Resistance
COM-to-GND Pulldown
V
= 1.5V, CTL = AGND
= 0V
DEL
V
DEL
V
DEL
V
DEL
1.5
2.5
kꢀ
= 1.5V, CTL = VCC
= 1.5V, CTL = AGND
300
200
600
360
SRC Input Current
µA
OPERATIONAL AMPLIFIERS
SUP Supply Range
MAX1075
6
18
4.2
6.5
12
V
V
VSUP Undervoltage Threshold
SUP Supply Current
3.8
4
4
Buffer configuration, V
= V
/2, no load
SUP
mA
mV
µA
V
POS
Input Offset Voltage
V
, V
= V
= V
/2, T = +25°C
A
NEG POS
SUP
SUP
Input Bias Current
V
, V
/2, T = +25°C
-1
0
+1
NEG POS
A
Input Common-Mode Voltage Range
Input Common-Mode Rejection Ratio
V
SUP
80
dB
V
SUP
350
-
Output-Voltage-Swing High
I
I
50mA
mV
OUT =
OUT =
Output-Voltage-Swing Low
Large-Signal Voltage Gain
Slew Rate
-50mA
350
mV
dB
V
= 1V to (V
- 1)V
80
45
20
OUT
SUP
V/µs
MHz
-3dB Bandwidth
Sourcing
Sinking
500
500
Short-Circuit Current
XAO CONTROL
mA
Falling edge at V = 5V
1.225
1.213
-1
1.250
1.250
1.275
1.287
+1
CC
RSTIN Threshold
V
Falling edge at V = 1.8V
CC
RSTIN Input Current
RSTIN Hysteresis
RST Output Voltage
RST Blanking Time
XAO UVLO
T
A
= +25°C
µA
mV
V
50
I
= 1mA
0.4
280
1.7
SINK
Counting from V
crossing 2.25V
160
220
1.5
ms
V
VCC
V
rising with hysteresis of 50mV
VCC
4
_______________________________________________________________________________________