Part Number Guide
FREQUENCY
MAH
14 pin DIP
Value Added Options
Blank = No Added Options
G = Gull-Wing (option 2)
CLXXX = Cut Leads
Symmetry
Blank = 40/60%
A = 45/55%
RoHS Compliant
Blank = Not Compliant
F = Is RoHS Compliant
Frequency
Stability
B = 47.5/52.5%
XXX = Lead Length Code
Supply Voltage
5 = +5.0 VDC
3 = +3.3 VDC
2 = +2.5 VDC
1 = +1.8 VDC
010 = ±10 ppm
020 = ±20 ppm
025 = ±25 ppm
050 = ±50 ppm
100 = ±100 ppm
Operating Temperature
Pin 1 Connection
Blank = No Connect
H = Tri-state
Blank = 0°C to +70°C
27 = -20°C to +70°C
48 = -40°C to +85°C
S = Standby
PLEASE CONSULT WITH MMD SALES DEPARTMENT FOR ANY OTHER PARAMETERS OR OPTIONS
Mechanical Details
20.70 [.815]
5.08 [.200]
MAX
MXXXXX
SYYWWL
XXXXX
5.08 [.200]
MIN
.50 [.020]
PIN CONNECTIONS
N/C, TRI-STATE or STANDBY
PIN 7 CASE GROUND
PIN 8 OUTPUT
PIN 1
15.24 [.600]
PIN 14 SUPPLY VOLTAGE
7
8
1
13.10 [.516]
MAX
7.62 [.300]
TRI-STATE OPERATION
14
PIN 1
PIN 8
LOGIC "1" OR N/C
OSCILLATION
LOGIC "0" OR GRD HIGH IMPEDANCE
DIMENSIONS IN BRACKET ARE IN INCHES
EXTERNAL BYPASS CAPACITOR RECOMMENDED
MMD Monitor/Quartztek
5458 Louie Lane, Reno, NV 89511
Phone: (775) 851-8880, Fax: (775) 851-8882, www.mmdcomp.com
Revision:
08/23/16 H
Pg 2 of 2
In the event of conflict, the requirements of this specification shall govern.
Revisions only with customer approval