MA100RWSeries
Wide 2:1 Input, 1.5W,
Single & Dual Output
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Key Features:
• 1.5W Output Power
• 2:1 Input Voltage Range
• 1,500 VDC Isolation
• 40 Standard Models
• High Efficiency
Parameter
Conditions
Min.
4.5
Typ.
5.0
Max.
9.0
Units
VDC
5 VDC Input
12 VDC Input
9.0
12.0
24.0
48.0
35
18.0
36.0
72.0
Input Voltage Range
24 VDC Input 18.0
48 VDC Input 36.0
Input Reflected Ripple Current
Input Filter
mA P - P
• Compact DIP Case
• -40°C to +85°C Operation
• Metal Case Available
• Low Cost
ꢀ (Pi) Filter
Output
Parameter
Output Voltage Accuracy
Line Regulation
Conditions
Min.
Typ.
1.0
0.5
0.5
0.5
60
Max.
Units
%
VIN = Min to Max
IOUT = 25% to 100%
See Note 1
%
Load Regulation
%
Cross Regulation
Ripple & Noise (20 MHz)
Temperature Coefficient
Output Short Circuit
General
%
See Note 2
mV P - P
%/°C
Alternate
Pin-Out
Available
0.02
Continuous (Autorecovery)
Parameter
Conditions
Min.
3 Seconds 1,500
500 VDC 1,000
Typ.
Max.
Units
VDC
M
Isolation Voltage, See Note 3
Isolation Resistance
Isolation Capacitance
Switching Frequency
Environmental
Parameter
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
3.5 kV Isolation
Models
100 kHz/0.1V
60
pF
100
400
kHz
Available
Conditions
Min.
Typ.
+25
Max.
+85
Units
°C
Ambient
Case
-40
+100
+125
°C
-40
°C
Free Air Convection
RH, Non-condensing
Humidity
95
%
Physical
Case Size
1.25 x 0.80 x 0.40 Inches (31.75 x 20.32 x 10.16 mm)
Non-Conductive Black Plastic (UL94-V0)
0.44 Oz (12.5g)
Case Material, Plastic
Weight, Plastic Case
Case Material, Metal
Weight, Metal Case
Reliability Specifications
Parameter
Nickel-Coated Copper With Non-Conductive Base (UL94-V0)
0.53 Oz (15g)
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Conditions
MIL HDBK 217F, 25°C, Gnd Benign 2.19
Min.
Typ.
Typ.
Max.
Units
MHours
MTBF
Absolute Maximum Ratings
Parameter
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Conditions
Min.
Max.
15.0
24.0
40.0
80.0
260
Units
VDC
°C
5 VDC Input -0.7
12 VDC Input -0.7
24 VDC Input -0.7
48 VDC Input -0.7
Input Voltage Surge (1 Sec)
Lead Temperature
1.5 mm From Case for 10 Sec
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com