Spec No.JELF243A-9130B-01
Reference Only
CHIP COIL(CHIP INDUCTORS)LQH3NPZ□□□□GRL SPECIFICATION
P1/8
Murata Standard Reference Specification【AEC-Q200】
1. Scope
This reference specification applies to Chip coil (Chip Inductors) LQH3NPZ_GR series for Automotive Electronics based on
AEC-Q200 except for Power train and Safety.
2. Part Numbering
(ex)
LQ
H
3N
P
Z
220
M
G
R
L
Product ID Structure Dimension Applications Category Inductance Tolerance Features Electrode Packaging
(L×W)
and
L: Φ180Taping
Characteristics
3. Rating
Operating Temperature Range.
(Ambient temperature; Self-temperature rise is not included)
(Product temperature; Self- temperature rise is included)
-40 to +105°C
-40 to +125°C
Storage Temperature Range.
-40 to +105°C
Inductance
Rated Current(mA)
Self
∗2 (Based on
DC
Resistance
(Ω)
∗1
Customer
Part Number
MURATA
Part Number
Resonant
Frequency
(MHz min)
ESD
5A:8kV
Temperature rise)
Tolerance
(Based on
(μH)
∗3 Ambient ∗4 Ambient
temperature temperature
(%)
Inductance
change)
(85℃)
(105℃)
LQH3NPZR47NGRL
LQH3NPZ1R0MGRL
LQH3NPZ1R5MGRL
LQH3NPZ2R2MGRL
LQH3NPZ3R3MGRL
LQH3NPZ4R7MGRL
LQH3NPZ6R8MGRL
LQH3NPZ100MGRL
LQH3NPZ150MGRL
LQH3NPZ220MGRL
LQH3NPZ330MGRL
LQH3NPZ470MGRL
0.47
1.0
1.5
2.2
3.3
4.7
6.8
10
N:±30% 0.047±20%
0.062±20%
180
100
80
50
30
27
25
20
15
10
8
2820
1700
1400
1180
1050
850
2540
1520
2080
2040
1730
1580
1520
1140
1120
900
1240
1220
1030
940
910
680
670
540
450
360
270
0.074±20%
0.087±20%
0.12±20%
0.14±20%
5A
M:±20%
0.23±20%
0.28±20%
0.39±20%
0.53±20%
0.86±20%
1.4±20%
720
570
15
480
22
390
750
33
320
600
47
5
260
460
∗1:When applied Rated current to the Products , Inductance will be within ±30% of initial inductance value range.
∗2:Keep the temperature (ambient temperature plus self-generation of heat) under 125℃.
∗3:When applied Rated current to the Products ,temperature rise caused by self-generated heat shall be limited
to 40℃ max. (Ambient temperature 85℃).
∗4:When applied Rated current to the Products ,temperature rise caused by self-generated heat shall be limited
to 20℃max. (Ambient temperature 85 to 105℃).
4. Testing Conditions
《Unless otherwise specified》
Temperature : Ordinary Temperature (15 to 35°C)
Humidity : Ordinary Humidity (25 to 85 %(RH))
《In case of doubt》
Temperature : 20 ± 2°C
Humidity
: 60 to 70 %(RH)
Atmospheric Pressure : 86 to 106 kPa
MURATA MFG.CO., LTD