POWER
LPS100-M Series
Data Sheet
150 Watts
Total Power: 80 - 150 Watts
Input Voltage: 90 - 264 Vac
120 - 300 Vdc
# of Outputs: Single
SPECIAL FEATURES
Medical and ITE safety approvals,
2X MOPP
Active power factor correction
2” x 4” footprint
Less than 1U high
EN61000-3-2 compliant
Remote sense
Power fail
Electrical Specifications
Input
Adjustable main output
Built-in Class B EMI filter
Overvoltage protection
Overload protection
Input range
Frequency
Inrush current
Efficiency
EMI/RFI
90 - 264 Vac; 120 - 300 Vdc
47 - 63 Hz
Thermal overload protection
Isolated 12 V fan output
LPX100 Enclosure kit available
50 A max., cold start @ 25 °C
88% typical at full load
FCC Class B conducted; CISPR22 Class B conducted;
POE isolation on main output of
LPS109-M
EN55022 Class B conducted; VDE0878PT3 Class B conducted
Safety ground leakage
current
275 μA @ 50/60 Hz, 264 Vac input
SAFETY
Output
TUV
UL
60950, 60601-1
60950, 60601-1
60950, 60601-1
Certificate & report
Mark (LVD)
Maximum power
100 W for convection (80 W for LPS102-M);
150 W with 30 CFM forced air (120 W for LPS102-M)
cULus
CB
Adjustment range
Fan output
10% minimum on the main outputs
12 V @ 1 A isolated, 10%
CE
Hold-up time
10 ms @ 150 W load, 120 Vac input
CQC
Mark
Overload protection
Short circuit protection on all outputs. Case overload
protected @ 110-160% above rating
Overvoltage protection
Logical Control
Power failure
15-35% above nominal output
Open collector logic signal goes high 100-500 msec after main output;
it goes low at least 6 msec before loss of regulation
Remote sense
Compensates for 0.5 V lead drop min. Will operate without remote
sense connected. Reverse connection protected.