Ordering number : ENN7817
SANYO Sem iconductors
DATA S HEET
Monolithic Linear IC
Five-Channel CD Actuator Driver
(BTL: 4 channels, H bridge: 1 channel)
LA6565
Overview
The LA6565 is a four-channel BTL plus one-channel H bridge actuator driver developed for use in CD and DVD
drives. The BTL driver channels 1 and 2 include built-in operational amplifiers allowing the LA6565 to support a wide
range of applications.
Application
• Five-channel (BTL: 4 channels, H bridge: 1 channel) CD motor driver
Features and Functions
• Five power amplifier channels on a single chip (Bridge connection (BTL): 4 channels, H bridge: 1 channel)
• IO max: 1 A
• Built-in level shifters (except for the H bridge channel)
• Muting circuits (output on/off, two systems)
(The muting circuits operate for the BTL amplifiers. They do not apply to the H bridge or regulator circuits.)
• Built-in regulator (Uses an external pnp transistor and is set with an external resistor.)
• Output voltage setting function (loading driver)
• Built-in independent operational amplifiers
• Thermal shutdown circuit
Specifications
Maximum Ratings at Ta = 25°C
Parameter
Symbol
Conditions
Ratings
Unit
V
Supply voltage
VCC max
14
0.8
2
Allowable power dissipation
Pd max
Independent IC
W
W
A
Specified PCB*
Maximum output current
Maximum input voltage
MUTE pin voltage
IO max
For each of the channel 1 to 4 and H bridge outputs
1
VINB
13
13
V
VMUTE
Topr
V
Operating temperature
Storage temperature
–30 to +85
°C
°C
Tstg
–55 to +150
Note *:Specified PCB (76.1mm × 114.3mm × 1.6mm), PCB meterial : glass epoxy
Recommended Operating Conditions at Ta = 25°C
Parameter
Symbol
VCC
Conditions
Ratings
5.6 to 13
Unit
V
Supply voltage
Any and all SANYO products described or contained herein do not have specifications that can handle
applications that require extremely high levels of reliability, such as life-support systems, aircraft's
control systems, or other applications whose failure can be reasonably expected to result in serious
physical and/or material damage. Consult with your SANYO representative nearest you before using
any SANYO products described or contained herein in such applications.
SANYO assumes no responsibility for equipment failures that result from using products at values that
exceed, even momentarily, rated values (such as maximum ratings, operating condition ranges, or other
parameters) listed in products specifications of any and all SANYO products described or contained
herein.
SANYO Electric Co.,Ltd. Sem iconductor Com pany
TOKYO OFFICE Tokyo Bldg., 1-10, 1 Chome, Ueno, Taito-ku, TOKYO, 110-8534 JAPAN
52404TN (OT) No.7817-1/8