5秒后页面跳转
KTS-22-G/CE PDF预览

KTS-22-G/CE

更新时间: 2022-05-14 21:51:55
品牌 Logo 应用领域
爱模 - MSYSTEM /
页数 文件大小 规格书
3页 104K
描述
Plug-in Signal Conditioners K-UNIT

KTS-22-G/CE 数据手册

 浏览型号KTS-22-G/CE的Datasheet PDF文件第1页浏览型号KTS-22-G/CE的Datasheet PDF文件第3页 
MODEL: KTS  
Zero adjustment: -5 to +5 % (front)  
Span adjustment: 95 to 105 % (front)  
At burnout: Downscale ≤ -10 %, Upscale ≥ 110 %  
Linearization: Standard  
50/60 ±2 Hz, approx. 2 VA  
DC: Operational voltage range: rating ±10 %  
ripple 10 %p-p max., approx. 2.6 W (110 mA at 24 V)  
Operating temperature: -5 to +55°C (23 to 131°F)  
Operating humidity: 30 to 90 %RH (non-condensing)  
Mounting: Surface or DIN rail  
Cold junction compensation: CJC sensor attached to the  
input terminals  
Weight: 350 g (0.77 lb)  
INPUT SPECIFICATIONS  
Minimum span: 3 mV  
PERFORMANCE in percentage of span  
Accuracy: ±0.3 % (at over 400°C or 750°F for R, S  
and PR; over 770°C or 1420°F for B)  
Cold junction compensation error  
Offset: Max. 1.5 times span  
Input resistance: 30 kΩ min.  
Burnout sensing: 0.1 μA  
(at 20°C ±10°C or 68°F ±18°F)  
Minimum span (in °C)  
(PR): min. span 370°C  
K (CA): min. span 75°C  
E (CRC): min. span 50°C  
J (IC): min. span 60°C  
T (CC): min. span 75°C  
B (RH): min. span 780°C  
R: min. span 360°C  
K, E, J, T, N: ±0.5°C or ±0.9°F  
S, R, PR: ±1°C or ±1.8°F  
Temp. coefficient: ±0.02 %/°C (±0.01 %/°F)  
(at over 400°C or 750°F for R, S and PR;  
over 770°C or 1420°F for B)  
Burnout response: ≤ 10 sec.  
Line voltage effect: ±0.1 % over voltage range  
Insulation resistance: ≥ 100 MΩ with 500 V DC  
Dielectric strength:  
S: min. span 380°C  
N: min. span 110°C  
1350 V AC @1 minute (input to output)  
2300 V AC @1 minute (input or output to power to ground)  
Minimum span (in °F)  
(PR): min. span 670°F  
K (CA): min. span 140°F  
E (CRC): min. span 90°F  
J (IC): min. span 110°F  
T (CC): min. span 140°F  
B (RH): min. span 1410°F  
R: min. span 650°F  
STANDARDS & APPROVALS  
EU conformity:  
EMC Directive  
EMI EN 61000-6-4  
EMS EN 61000-6-2  
Low Voltage Directive  
EN 61010-1  
S: min. span 690°F  
Installation Category II  
Pollution Degree 2  
N: min. span 200°F  
Input or output to power: Reinforced insulation (300 V)  
Input to output: Basic insulation (300 V)  
RoHS Directive  
Note: The described accuracy may be partially not satisfied  
when the temperature ranges below 0°C. Consult factory.  
OUTPUT SPECIFICATIONS  
■ DC Current: 0 – 20 mA DC  
Minimum span: 1 mA  
Offset: Max. 1.5 times span  
Load resistance: Output drive 15 V max.  
DC Voltage: -10 – +12 V DC  
Minimum span: 5 mV  
Offset: Max. 1.5 times span  
Load resistance: Output drive 1 mA max. at ≥ 3 V  
INSTALLATION  
Power input  
AC: Operational voltage range: rating ±10 %,  
KTS SPECIFICATIONS  
ES-3531-CE Rev.11 Page 2/3  
https://www.m-system.co.jp/  

与KTS-22-G/CE相关器件

型号 品牌 描述 获取价格 数据表
KTS-22-G/K MSYSTEM Plug-in Signal Conditioners K-UNIT

获取价格

KTS-22-G/Q MSYSTEM Plug-in Signal Conditioners K-UNIT

获取价格

KTS-22-H MSYSTEM Plug-in Signal Conditioners K-UNIT

获取价格

KTS-22-H/B MSYSTEM Plug-in Signal Conditioners K-UNIT

获取价格

KTS-22-H/BL MSYSTEM Plug-in Signal Conditioners K-UNIT

获取价格

KTS-22-H/BN MSYSTEM Plug-in Signal Conditioners K-UNIT

获取价格