KP 1830
AC and Pulse Film Foil Capacitors
KP Radial Potted Type
Vishay Roederstein
RECOMMENDED PACKAGING
TYPE OF
PACKAGING
HEIGHT (H)
(mm)
REEL DIAMETER
(mm)
ORDERING CODE
PITCH
5
LETTER
CODE
EXAMPLE
G
W
-
Ammo
Reel
18.5
18.5
-
S (1)
350
-
KP 1830-310-065-G
KP 1830-310-065-W
KP 1830-310-065
X
X
X
Bulk
Note
(1) S = Box size 55 mm x 210 mm x 340 mm (W x H x L)
EXAMPLE OF ORDERING CODE
TYPE
CAPACITANCE CODE
VOLTAGE CODE
63
TOLERANCE CODE
PACKAGING CODE
KP 1830
210
1
G
Tolerance codes: 1 = 1 % (F); 2 = 2 % (G); 3 = 2.5 % (H); 4 = 5 % (J); 5 = 10 % (K)
Note
For detailed tape specifications refer to “Packaging Information” www.vishay.com/doc?28139 or end of catalog
MOUNTING
Normal Use
The capacitors are designed for mounting on printed-circuit boards. The capacitors packed in bandoliers are designed for
mounting on printed-circuit boards by means of automatic insertion machines.
For detailed tape specifications refer to “Packaging information” www.vishay.com/doc?28139 or end of catalog
Specific Method of Mounting of Withstand Vibration and Shock
In order to withstand vibration and shock tests, it must be ensured that the stand-off pips are in good contact with the
printed-circuit board.
• For pitches ≤ 15 mm the capacitors shall be mechanically fixed by the leads
• For larger pitches the capacitors shall be mounted in the same way and the body clamped
Space Requirements on Printed-Circuit Board
The maximum length and width of film capacitors is shown in the drawing:
• Eccentricity as in drawing. The maximum eccentricity is smaller than or equal to the lead diameter of the product concerned
• Product height with seating plane as given by “IEC 60717” as reference: hmax. ≤ h + 0.4 mm or hmax. ≤ h’ + 0.4 mm
bmax. = b + 0.3 mm
Eccentricity
Imax. = I + 0.3 mm
Storage Temperature
• Storage temperature: Tstg = - 25 °C to + 40 °C with RH maximum 80 % without condensation
Ratings and Characteristics Reference Conditions
Unless otherwise specified, all electrical values apply to an ambient free temperature of 23 °C 1 °C, an atmospheric pressure
of 86 kPa to 106 kPa and a relative humidity of 50 % 2 %.
For reference testing, a conditioning period shall be applied over 96 h 4 h by heating the products in a circulating air oven at
the rated temperature and a relative humidity not exceeding 20 %.
Document Number: 26016
Revision: 16-Jan-09
For technical questions, contact: dc-film@vishay.com
www.vishay.com
215