MODEL: JDL
configurable with JXCON.)
[3] POWER INPUT
AC Power
B: 100 V AC
C: 110 V AC
D: 115 V AC
F: 120 V AC
G: 200 V AC
H: 220 V AC
J: 240 V AC
SUPPLY OUTPUT
Output voltage: 24 – 28 V DC with no load
Current rating: ≤ 22 mA DC
• Shortcircuit Protection
Current limited: 30 mA max.
Protected time duration: No limit
DC Power
INPUT SPECIFICATIONS
S: 12 V DC
■ DC Current: Input resistor incorporated
R: 24 V DC
V: 48 V DC
OUTPUT SPECIFICATIONS
■ DC Current: 0 – 20 mA DC
[4] OPTIONS
blank: none
Minimum span: 1 mA
Offset: Max. 1.5 times span
/Q: With options (specify the specification)
Load resistance: Output drive 15 V max.
■ DC Voltage: -10 – +20 V DC
Span: Min. 5 mV, max. 20 V
SPECIFICATIONS OF OPTION: Q (multiple selections)
COATING (For the detail, refer to M-System's web site.)
/C01: Silicone coating
Offset: Max. 1.5 times span
Load resistance: Output drive 1 mA max.; at ≥ 0.5 V
/C02: Polyurethane coating
/C03: Rubber coating
LINEARIZATION
TERMINAL SCREW MATERIAL
/S01: Stainless steel
• No linearization: The output is proportional to the input.
• Segment data: 16 points (15 segments) max. within the
range of -15.00 to +115.00 % input or output represented
as percentage of fullscale
RELATED PRODUCTS
• Programming Unit (model: PU-2x)
• Square root extraction
• PC configurator software (model: JXCON)
Downloadable at M-System’s web site.
A dedicated cable is required to connect the module to the
PC. Please refer to the internet software download site or
the users manual for the PC configurator for applicable
cable types.
Low-end cutout: 5 % (output); curve characteristics as in the
figure below
■ Square root extraction
GENERAL SPECIFICATIONS
Construction: Plug-in
6%
5%
Connection: M3.5 screw terminals
Screw terminal: Chromated steel (standard) or stainless
steel
0
INPUT
Housing material: Flame-resistant resin (black)
Isolation: Input to output to power
Overrange output: Approx. -10 to +120 % at 1 – 5 V
Zero adjustment: -5 to +5 % (front)
Span adjustment: 95 to 105 % (front)
Linearization: 16 points max. represented as percentage of
full-scale
Adjustments: Programming Unit (model: PU-2x);
linearization data, zero and span, simulating output, etc.
(Refer to the users manual of JXCON for the adjustments
JDL SPECIFICATIONS
ES-1668 Rev.12 Page 2/4
http://www.m-system.co.jp/