ICS650-22
PVR and STB Clock Source
Absolute Maximum Ratings
Stresses above the ratings listed below can cause permanent damage to the ICS650-22. These ratings,
which are standard values for ICS commercially rated parts, are stress ratings only. Functional operation of
the device at these or any other conditions above those indicated in the operational sections of the
specifications is not implied. Exposure to absolute maximum rating conditions for extended periods can
affect product reliability. Electrical parameters are guaranteed only over the recommended operating
temperature range.
Item
Rating
Supply Voltage, VDD
All Inputs and Outputs
7 V
-0.5 V to VDD+0.5 V
-40 to +85°C
-65 to +150°C
125°C
Ambient Operating Temperature
Storage Temperature
Junction Temperature
Soldering Temperature
260°C
Recommended Operation Conditions
Parameter
Min.
Typ.
-
Max.
+70
Units
°C
Ambient Operating Temperature
Power Supply Voltage (measured in respect to GND)
0
+3.0
+3.3
+3.6
V
DC Electrical Characteristics
Unless stated otherwise, VDD = 3.3V ±10%, Ambient Temperature 0 to +70°C
Parameter
Symbol
Conditions
Min.
Typ.
Max.
Units
Operating Voltage
VDD
3.0
3.3
3.6
V
V
Input High Voltage
V
VDD/2+1 VDD/2
IH
Input Low Voltage
V
VDD/2 VDD/2-1
0.5
V
IL
Output High Voltage
Output Low Voltage
Output High Voltage
Operating Supply Current
V
I
I
I
= -25 mA
= +25 mA
= -8 mA
2.4
V
OH
OH
OL
OH
V
V
V
OL
OL
VDD-0.4
V
I
No Load, OE=1
No Load, OE=0
Each output
29
13
mA
mA
mA
kΩ
DD
Short Circuit Current
I
±70
390
OS
Internal Pull-up Resistor
R
Input select
PU
MDS 650-22 D
3
Revision 051004
Integrated Circuit Systems, Inc. ● 525 Race Street, San Jose, CA 95126 ● tel (408) 297-1201 ● www.icst.com