TECHNICAL
DATA
1
TEMPERATURE AND RELATIVE HUMIDITY SENSOR HTS2030SMD
Meets RoHS regulations
Based on a unique capacitive cell for humidity measurement and a Negative
Temperature Coefficient (NTC) thermistor for temperature measurement, this dual purpose
relative humidity / temperature miniaturized sensor is designed for high volume, cost
sensitive applications with tight space constraints. It is useful in all applications where
dew point, absolute humidity measurements or humidity compensation are required.
MAIN FEATURES
● Miniature Surface mount SMD package.
● Lead free components.
● Full interchangeability with no calibration required in standard conditions.
● Instantaneous desaturation after long periods in saturation phase.
● Compatible with automatized assembly processes, including Pb free
wave soldering and reflow processes (1)
● High reliability and long term stability.
● Patented solid polymer structure.
● Suitable for linear voltage or frequency output circuitry.
● Fast response time and very low temperature coefficient.
● Part may be washed with distilled water.
● Individual marking for compliance to stringent traceability requirements.
(1) soldering temperature profiles available on request / contact us at application@humirel.com
Operating Range
MAXIMUM RATINGS
100
90
Ratings
Symbol
Value
Unit
80
70
60
50
40
30
20
10
0
Operating Temperature
Storage Temperature
Supply Voltage (Peak)
Ta
Tstg
Vs
-60 to 140
-60 to 140
10
°C
°C
Vac
Humidity Operating Range
RH
0 to 100
% RH
-60
-40
-20
0
20
40
60
80
100
120
140
160
Temperature in °C
CHARACTERISTICS
Humidity sensor (Ta = 25°C, measurement frequency @ 10kHz unless otherwise noted)
Characteristics
Humidity measuring range
Symbol
Min.
Typ.
Max.
Unit.
%RH
V
RH
1
99
Supply voltage
Vs
10
Nominal capacitance @ 55% RH*
Temperature coefficient
C
177
180
183
0.01
pF
Tcc
pF/°C
Averaged Sensitivity from 33% to 75% RH
Leakage current (Vcc = 5 Volts)
∆C /% RH
0.31
10
pF/% RH
nA
I
1
+/-1
5
Recovery time after 150 hours of condensation
Humidity Hysteresis
tr
s
%RH
%RH/yr
s
Long term stability
τ
+/-0.5
3
Time constant (33 to 80 % RH, still air @ 63%)
Deviation to typical response curve (10% to 90%) RH)
ta
+/-2
%RH
*tighter specification available on request
HUMIREL HPC055 Rev0 June 2004