H HiTRON
AC/DC EXTERNAL WALLMOUNT ADAPTER USA OR
EUROPEAN INPUT SINGLE OUTPUT 16-18 WATTS
SWITCHING POWER SUPPLIES HES16B & HES16C SERIES
FEATURES:
ꢀ LOW COST WALLMOUNT ADAPTER
ꢀ DIVERSE AC PLUGS AVAILABLE
ꢀ MEET DIVERSE SAFETY STANDARDS
ꢀ EMI MEET EN 55022 OR FCC CLASS B
ꢀ CE MARKING COMPLIANCE
SPECIFICATION
INPUT SPECIFICATION
OUTPUT SPECIFICATION
Input Voltage: HES16B typical 90-132Vac,rating 120Vac.
HES16C typical180-264Vac,rating 230Vac.
Input Connector: Wallmount Format.
Output Voltage: See Ratings Chart.
Output Current: See Ratings Chart.
Output Wattage: 16-18 Watts typical.
Output Connector: Optional.
HES16B:WM1(U.S.2-blade)/WM2(U.S.3-blade).
HES16C:WM3(Euro-stecker)/WM4(Schuko-stecker)/
WM5(UK)/WM5G(UK)/WM6,6G(Australia).
Input Frequency: 47-63Hz.
Line Regulation: 0.65% typical.
Load Regulation: ±1.5% typical.
Noise & Ripple: 1.0% typical peak to peak.
OVP: Built-in, By Zener diode clamping.
Adjustability: Factory set.
Inrush Current: HES16B: 18.0A @ 115Vac typical.
HES16C: 28.0A @ 230Vac typical. (by thermister)
Input Current: HES16B 0.234A @ 115Vac typical.
HES16C 0.133A @ 230Vac typical.
Overload Protection (OLP):
Fully protected against output overload and short circuit.
OLP set at about 120-150% max. load.
Consult the factory for special OLP setting.
Dielectric Withstand: Meet IEC60950.
EMI: Meet EN 55022 or FCC Class B.
Hold-up Time: 27.6mS@115Vac/53.6mS@230Vac typical.
GENERAL SPECIFICATION
Efficiency: 80% typical.
Operating Temperature: 0 to +40°C with no derating.
Storage Temperature: -20 to +85°C.
Temperature Coefficient: 0.04% /°C typical.
Cooling: Free air convection.
Switching Frequency: 65-75K Hz.@ full load typical.
Circuit Topology: Free-running flyback circuit.
Transient Response: Output voltage returns typ. 6mS.
following a 25% load change.
Construction: Impact resistant thermo-plastic
enclosure case.
Safety Standard: UL1950/EN60950. Class I or II.
Power Density: 1.45 Watts / Cubic inch.
Wallmount format.
NOTE:(1) All measurements are at nominal input, full load, and +25°C. unless otherwise specified.
(2) Load regulation is measured at 230Vac or 120Vac in percentage to indicate the change in output voltage as the load varied from half load to full load (±%).
(3) The exact obtainable load regulation depends upon the output cord selected and load current. Upper data are for 6 ft. (2 m) cord AWG#18 wires.
For the details of safety approval, please consult the factory.
Due to requests in market and advances in technology, specifications subject to change without notice.
-21-