OCXO Sine Output VHF
HCD380
Specifications
2011/65/EU
Product
HCD380
Option
Codes
Parameters
Frequency range:
30.0 ~ 100MHz
Ageing per day (at despatch):
<ꢀ5x10-9
B
C
D
<ꢀ3x10-9
<ꢀ1x10-9
Frequency stability:
<ꢀ1 to 5x10-7 per year
36.10 (max)
27.20 (max)
<ꢀ5x10-9 per 10% change in VDD
Temperature stability:
< 5x10-8
< 2x10-8
< 1x10-8
N
P
R
15.00
(max)
0.50
Operating temperature range:
0 to +50°C
5.00
0.80Ø
17.80
A
C
F
15.00
-10 to +60°C
-20 to +70°C
25.40
PIN
1
CONNECTION
Freq adjustment
Ref. voltage out
Supply
Storage temperature range:
-40 to +90°C
3
2
1
4
5
8.90
8.90
2
Output waveform:
Sine wave, 7dBm (±1dBm) into 50Ω
3
4
RF output
Frequency adjustment:
5
Ground & case
±5x10-7 (typ) over +0.5 to +6.0V
(sufficient for 10 years ageing min)
Stabilised +6.0V supply provided
BOTTOM VIEW
Supply voltage (VDD): +9V (±0.5V)
+12V (±0.5V)
M
N
P
+15V (±0.5V)
+18V (±0.5V)
Features
R
Power consumption:
4.5W max at switch on
1.0W typ when stabilised at +25°C
-160dBc/Hz noise floor
Frequencies up to 100MHz
No multiplier
Warm up:
<ꢀ5x10-8 after 10mins at +25°C
Allan deviation (ADEV), 1 sec:
Standard European IEC CO-08 pin-out
Custom options available
<ꢀ2x10-11
Phase noise (@ 50.0MHz):
<ꢀ-75 dBc/Hz @ꢀ1Hz
<ꢀ-105 dBc/Hz @ꢀ10Hz
<ꢀ-135 dBc/Hz @ꢀ100Hz
<ꢀ-150 dBc/Hz @ꢀ1kHz
<ꢀ-160 dBc/Hz @ꢀ10kHz
<ꢀ-160 dBc/Hz @ꢀ50kHz
Shock:
IEC 68-2-27 Test Ea
50G for 11ms
Vibration:
IEC 68-2-06 Test Fc
10-55Hz, 1.5mm. 55-500Hz, 10G
Standard. Optional - Please specify required code(s) when ordering
Ordering Information
Part No, or product name + option codes + frequency
eg: HCD380/BPCN 100MHz
HCD380/CRCN 50.0MHz
Option code X (eg HCD380/X) denotes a custom specification.
Some combinations of frequency and specification may not be avail-
able, or may be subject to extended leadtimes
Tel: +44 1460 256 100
Fax: +44 1460 256 101
E-mail: sales@golledge.com
Web: www.golledge.com
14 Jan 2016