GT05 Series
Gate Drive Transformer
FEATURES
- 8.7 mm creepage/clearance
PACKAGING
-Reel Diameter: 13"
-Reel Width:
-Pieces Per Reel: 600
24mm
- Optimized for frequencies from
40 kHz to 350 kHz
- Suitable for pick and place applications
APPLICATIONS
- Gate Drive Transformer
- Signal Transformer Across Isolation Barrier
Mechanical
Recommend PCB Layout
Schematic
4
1
TOP VIE W
2.7
5
Gate
1
4
4
5
1
6
7
Drive
1.7(X6)
GT05-XXX-XXX
RXT-2 ICE
YYWW
6.8 MAX
12.1
Gate
8
8
2.0(X6)
13.0 MAX
8.1
5
8
11.0 MAX
Electrical Specifications
Part
Number
Turns Ratio Drive Ind.1
Drive:Gate (µH, min.) (mΩ, max.) (nH, max.)
DCR
Lkg. Ind.
E-T Prod5
(V-µs)
Hi-Pot
Drive:Gate
Hi-Pot
Gate:Gate
GT05-111-049
GT05-111-100
GT05-122-053
1:1:1
1:1:1
882
2000
162
720:720
1430:1300
360:720
300
470
170
49
100
53
3750 Vac
1,500 Vdc
1,500 Vdc
1,500 Vdc
3750 Vac
3750 Vac
1:2.5:2.5
1. Tested at 100kHz, 0.1Vrms.
2. Electrical specifications at 25°C.
3. Operating range: -40° C to +130° C.
4. Meets UL 94V-0.
5. E-T product rating is for secondary (gate) windings in a bipolar drive application at 25°C. Derate
the E-T product rating by 20% for operation at 100°C.
6. Meets Class F (155°C) insulation system requirements.
Specifications subject to change without notice.
800.729.2099 tel
www.icecomponents.com
(8/11) GT05-1