G70D
G70D
3 CHARACTERISTICS
Part number
G70D-VSOC16/
G70D-SOC16 (-1)
G70D-SOC16(-1)
G70D-VFOM16/
G70D-FOM16 (-1)
G70D-FOM16 (-1)
Output type
Relay outputs
Power MOSFET Relay outputs
Contact form
16 points (SPST-NO x 16)
Single
Contact mechanism
Contact resistance
Insulation method
Must operate time
100 m max. measured at 1 A, 5 VDC
Ω
Photocoupler
6 ms max.
10 ms max. at 23 C (73.4 F) ambient
°
°
temperature
Release time
10 ms max. at 23 C (73.4 F) ambient
temperature
10 ms max.
°
°
Output ON-resistance
2.4 max.
Ω
Leakage current at OFF-state
Max. switching frequency
10 µA max. at 125 VDC
Mechanical: 18,000 operations/hr
Rated load: 1,800 operations/hr
Insulation resistance
Dielectric strength
100 M min. (at 500 VDC)
Ω
2,000 VAC for 1 min between coil and contact 2,000 VAC for 1 min between input and output
terminals
Noise immunity
Power input (normal mode):
Power input (common mode):
Input cable (coiling):
600 V for 10 min with a pulse width of 100 ns/1 µs
1.5 kV for 10 min with a pulse width of 100 ns/1 µs
1.5 kV for 10 min with a pulse width of 100 ns/1 µs
600 V for 10 min with a pulse width of 100 ns/1 µs
Unit body (coiling):
Vibration resistance
Shock resistance
Destruction 10 to 55 Hz, 1.0--mm double amplitude for 2 hrs each in X, Y, and Z directions
Malfunction 10 to 55 Hz, 0.75--mm double amplitude for 2 hrs each in X, Y, and Z directions
2
Destruction 300 m/s
2
Malfunction 100 m/s
+10%
Operating voltage range
Current consumption
24 VDC
/
--15%
Approx. 170 mA at 24 Approx 300 mA at 24 Approx. 125 mA at 24 Approx. 300 mA at 24
VDC (See Note 2) VDC (See Note 2) VDC (See Note 3) VDC (See Note 3)
Cable length
LED color
Between block and controller: 5 m max. (reference value for AWG28)
Between block and external device: Dependent on load
Operation indicator:
orange
Operation indicator:
orange
Operation indicator:
orange
Operation indicator:
orange
Power supply: green
Power supply: green
Coil surge absorber
Diode (600 V, 1 A)
Diode (400 V, 0.3 A)
Diode (600 V, 1 A)
Diode (400 V, 0.3 A)
Ambient
temperature
Operating
Storage
-- 2 5 C to 55 C (--13 F 0 C to 55 C (32 F to
-- 2 5 C to 55 C (--13 F 0 C to 55 C (32 F to
° ° ° ° ° °
°
°
°
°
°
°
to 131 F) with no
icing or condensation or condensation
131 F) with no icing
to 131 F) with no
131 F) with no icing
°
°
°
°
icing or condensation or condensation
-- 2 5 C to 65 C (--13 F -- 2 0 C to 65 C (--4 F
-- 2 5 C to 65 C (--13 F -- 2 0 C to 65 C (--4 F
°
°
°
°
°
°
°
°
°
°
°
°
to 149 F) with no
to 149 F) with no
to 149 F) with no
to 149 F) with no
°
°
°
°
icing or condensation icing or condensation icing or condensation icing or condensation
Ambient humidity
Mounting strength
Operating
45% to 85% RH 35% to 85% RH 45% to 85% RH 35% to 85% RH
No damage when 49 N pull load was applied for 1 s in all directions (except for 9.8 N min. in
direction of rail)
Terminal strength
Tightening torque: 0.78 to 1.18 N : m
Pull strength:
49 N for 1 min
Weight (See Note 4)
Approx. 280 g
Approx. 200 g
Approx. 280 g
Approx. 200 g
Note: 1. The above values are initial values.
2. Current consumption is when all points are ON and includes G6D Relay coil current but does not include any external load
current.
3. Current consumption is when all points are ON and includes G3DZ input current but does not include any external load current.
4. The Relay Output Block weighs approximately 315 g with the Expansion Terminal Block mounted.
4