■ Coil Ratings
Non-latching, Standard and Reverse-contact Models G6Z-1P(E), G6Z-1F(E)
Rated
voltage
(VDC)
Rated
current
(mA)
Coil
resistance
(Ω)
Must operate
voltage
Must dropout
voltage
Maximum
voltage
(VDC)
Power
consumption
(mW)
(VDC)
(VDC)
3
66.7
44.4
40.0
22.2
16.7
8.3
45
75% max. of
rated voltage
10% min. of
rated voltage
150% of rated
voltage
Approx. 200
4.5
5
101
125
9
405
12
24
720
2,880
Single Coil Latching Models G6ZU-1P(E), G6ZU-1F(E)
Rated
voltage
(VDC)
Rated
current
(mA)
Coil
resistance
(Ω)
Must set
voltage
(VDC)
Must reset
voltage
(VDC)
Maximum
voltage
(VDC)
Power
consumption
(mW)
3
66.7
44.4
40.0
22.2
16.7
8.3
45
75% max. of
rated voltage
75% max. of
rated voltage
150% of rated
voltage
Approx. 200
4.5
5
101
125
9
405
12
24
720
2,880
Dual Coil Latching Models G6ZK-1P(E), G6ZK-1F(E)
Rated
voltage
(VDC)
Rated
current
(mA)
Coil
resistance
(Ω)
Must set
voltage
(VDC)
Must reset
voltage
(VDC)
Maximum
voltage
(VDC)
Power
consumption
(mW)
3
120
80
72
40
30
15
25
56
69
75% max. of
rated voltage
75% max. of
rated voltage
150% of rated
voltage
Approx. 360
4.5
5
9
225
12
24
400
1,600
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of 10%.
2. The operating characteristics are measured at a coil temperature of 23°C.
3. The maximum voltage is the highest voltage that can be imposed on the relay coil instantaneously.
4. The voltage measurements for operate/release and set/reset are the values obtained for instantaneous changes in the voltage
(rectangular wave).
High-frequency Relay G6Z