G3VM-61A1/D1
G3VM-61A1/D1
■Absolute Maximum Ratings (Ta = 25LC)
Item
Symbol
Rating
Unit
Measurement Conditions
Note:
1. The dielectric strength between the input and
output was checked by applying voltage be-
tween all pins as a group on the LED side and
all pins as a group on the light-receiving side.
Input
LED forward current
IF
50
1
mA
Repetitive peak LED forward IFP
current
A
100 ꢀs pulses, 100 pps
Ta O 25LC
LED forward current reduc-
tion rate
ꢁ I /LC
ꢂ0.5
mA/LC
F
LED reverse voltage
VR
5
V
Connection temperature
Tj
125
60
LC
Output Output dielectric strength
Continuous load current
VOFF
IO
V
500
mA
mA/LC
LC
ON current reduction rate
Connection temperature
ꢁ ION/LC ꢂ5.0
Ta O 25LC
Tj
125
Dielectric strength between input and
output (See note 1.)
VI-O
2,500
Vrms
AC for 1 min
Operating temperature
Storage temperature
Ta
ꢂ40 to +85 LC
ꢂ55 to +125 LC
With no icing or condensation
With no icing or condensation
10 s
Tstg
---
Soldering temperature (10 s)
260
LC
■Electrical Characteristics (Ta = 25LC)
Item
Symbol
Mini-
mum
Typical
Maxi-
mum
Unit
Measurement
conditions
Note:
2. Turn-ON and Turn-OFF
Input
LED forward voltage
VF
1.0
1.15
---
1.3
V
IF = 10 mA
Times
Reverse current
IR
---
---
---
---
10
---
3
ꢀA
pF
mA
ꢃ
VR = 5 V
IF
1
4
3
RL
VDD
Capacity between terminals
Trigger LED forward current
CT
IFT
RON
30
1.6
1
V = 0, f = 1 MHz
IO = 500 mA
VOUT
2
Output Maximum resistance with output ON
2
IF = 5 mA,
IO = 500 mA
Current leakage when the relay is
open
ILEAK
---
---
1.0
ꢀA
VOFF = 60 V
IF
Capacity between I/O terminals
Insulation resistance
CI-O
RI-O
---
0.8
---
---
---
pF
f = 1 MHz, Vs = 0 V
90%
1,000
Mꢃ
VI-O = 500 VDC,
RoH ? 60%
VOUT
10%
tON
tOFF
Turn-ON time
Turn-OFF time
tON
---
---
0.8
0.1
2.0
0.5
ms
ms
IF = 5 mA, RL = 200 ꢃꢄꢅ
VDD = 20 V (See note 2.)
tOFF
■Recommended Operating Conditions
Use the G3VM under the following conditions so that the Relay will operate properly.
Item
Symbol
VDD
Minimum
Typical
Maximum
Unit
Output dielectric strength
---
5
---
7.5
---
---
48
25
V
Operating LED forward current
Continuous load current
Operating temperature
IF
mA
mA
LC
IO
Ta
---
500
65
ꢂ 20
■Engineering Data
Load Current vs. Ambient Temperature
■Safety Precautions
Refer to page 6 for precautions common to all G3VM models.
G3VM-61A1(D1)
600
500
400
300
200
100
0
−20
0
20
40
60
80
100
Ambient temperature (°C)
9