描述
Solid State Relays

G3M 技术参数

生命周期:Obsolete包装说明:HERMETIC SEALED, GLASS, CASE G-3, 2 PIN
针数:2Reach Compliance Code:unknown
ECCN代码:EAR99HTS代码:8541.10.00.80
风险等级:5.59Is Samacsys:N
应用:GENERAL PURPOSE外壳连接:ISOLATED
配置:SINGLE二极管元件材料:SILICON
二极管类型:RECTIFIER DIODE最大正向电压 (VF):1.1 V
JESD-30 代码:E-LALF-W2最大非重复峰值正向电流:125 A
元件数量:1相数:1
端子数量:2最高工作温度:175 °C
最低工作温度:-55 °C最大输出电流:3 A
封装主体材料:GLASS封装形状:ELLIPTICAL
封装形式:LONG FORM认证状态:Not Qualified
最大重复峰值反向电压:1000 V最大反向恢复时间:3 µs
子类别:Rectifier Diodes表面贴装:NO
端子形式:WIRE端子位置:AXIAL
Base Number Matches:1

G3M 数据手册

 浏览型号G3M的Datasheet PDF文件第2页浏览型号G3M的Datasheet PDF文件第3页浏览型号G3M的Datasheet PDF文件第4页浏览型号G3M的Datasheet PDF文件第5页浏览型号G3M的Datasheet PDF文件第6页浏览型号G3M的Datasheet PDF文件第7页 
Certain Precautions on Specifications and Use  
1. Suitability for Use. Seller shall not be responsible for conformity with any stan- 2. Programmable Products. Seller shall not be responsible for the user's pro-  
dards, codes or regulations which apply to the combination of the Product in  
gramming of a programmable product, or any consequence thereof.  
Buyer's application or use of the Product. At Buyer's request, Seller will pro- 3. Performance Data. Performance data given in this publication is provided as  
vide applicable third party certification documents identifying ratings and limi-  
tations of use which apply to the Product. This information by itself is not  
sufficient for a complete determination of the suitability of the Product in com-  
bination with the end product, machine, system, or other application or use.  
a guide for the user in determining suitability and does not constitute a war-  
ranty. It may represent the result of Seller's test conditions, and the users must  
correlate it to actual application requirements. Actual performance is subject to  
Seller's Warranty and Limitations of Liability.  
Buyer shall be solely responsible for determining appropriateness of the par- 4. Change in Specifications. Product specifications and accessories may be  
ticular Product with respect to Buyer's application, product or system. Buyer  
shall take application responsibility in all cases but the following is a non-  
exhaustive list of applications for which particular attention must be given:  
(i) Outdoor use, uses involving potential chemical contamination or electrical  
interference, or conditions or uses not described in this document.  
(ii) Energy control systems, combustion systems, railroad systems, aviation  
systems, medical equipment, amusement machines, vehicles, safety  
equipment, and installations subject to separate industry or government  
regulations.  
(iii) Use in consumer products or any use in significant quantities.  
(iv) Systems, machines and equipment that could present a risk to life or  
property. Please know and observe all prohibitions of use applicable to this  
product.  
changed at any time based on improvements and other reasons. It is our prac-  
tice to change part numbers when published ratings or features are changed,  
or when significant construction changes are made. However, some specifica-  
tions of the Product may be changed without any notice. When in doubt, spe-  
cial part numbers may be assigned to fix or establish key specifications for  
your application. Please consult with your Seller representative at any time to  
confirm actual specifications of purchased Product.  
5. Errors and Omissions. The information in this publication has been carefully  
checked and is believed to be accurate; however, no responsibility is assumed  
for clerical, typographical or proofreading errors, or omissions.  
6. RoHS Compliance. Where indicated, our products currently comply, to the  
best of our knowledge as of the date of this publication, with the requirements  
of the European Union's Directive on the Restriction of certain Hazardous  
Substances ("RoHS"), although the requirements of RoHS do not take effect  
until July 2006. These requirements may be subject to change. Please consult  
our website for current information.  
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS  
RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM  
AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT  
THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE  
INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.  
Complete “Terms and Conditions of Sale” for product purchase and use are on Omron’s website  
at http://www.components.omron.com – under the “About Us” tab, in the Legal Matters section.  
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.  
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.  
OMRON ON-LINE  
Global - http://www.omron.com  
USA - http://www.components.omron.com  
OMRON ELECTRONIC  
COMPONENTS LLC  
55 E. Commerce Drive, Suite B  
Schaumburg, IL 60173  
847-882-2288  
06/09  
Specifications subject to change without notice  
Printed in USA  
Cat. No. X301-E-1  
Solid State Relays G3M  

与G3M相关器件

型号 品牌 描述 获取价格 数据表
G3M-102PL-4-US-4 ETC

获取价格

G3M-102PL-4-UTU-4 ETC

获取价格

G3M-102PL-US OMRON Solid State Relays

获取价格

G3M-102PL-US-4 OMRON Solid State Relays

获取价格

G3M-102PL-US-4DC12 OMRON Trigger Output SSR, 1-Channel, 2000V Isolation, SIP-4

获取价格

G3M-102PL-US-4DC24 OMRON Trigger Output SSR, 1-Channel, 2000V Isolation, SIP-4

获取价格