H-XS-1W&G-XS-1W Series
OUTPUT CHARACTERISTICS
Parameter
Conditions
Min.
Typ.
Max.
1
Units
W
Rated Power1
Voltage Set Point
Line regulation
TA=-40°C to 60°C
See tolerance envelope
High Vin to low Vin
1.0
10.0
7.0
1.2
%%
%
10% load to rated load,xx03
10% load to rated load,0505
10% load to rated load,0509,0512,0515
10% load to rated load,12xx
10% load to rated load,5V output types
10% load to rated load,9V output types
10% load to rated load,12V output types
10% load to rated load,15V output types
All types
15.0
10.0
10.0
7.0
Load regulation
Single outputs
6.0
5.0
10.0
6.0
15.0
10.0
10.0
10.0
Load regulation
Dual outputs
%
6.0
6.0
Zero Load Power
250
MW
ISOLATION CHARACTERISTICS
Parameter
Conditions
Min.
5200
Typ.
1
Max.
Max.
Max.
Units
Isolation test voltage
Resistance
Flash tested for 1 second
Viso=500VDC
VDC
GΩ
GENERAL CHARACTERISTICS
Parameter
Conditions
Min.
Typ.
Units
kHz
Single output
Dual output
45
70
Switching frequency
TEMPERATURE CHARACTERISTICS
Parameter
Conditions
Min.
Typ.
Units
Specification
Storage
All output types
-40
-55
60
130
33
°C
Case Tempetature above
All output types
TEMPERATURE DERATING GRAPH
TOLERANCE ENVELOPE
H-XS/G-XS-1W
3.3V in,3V out type only
1.See derating graph.
All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.Another 24V& 48V products, please inquire Our technical department!
http://www.microdc.cn
Technical Enquiries-Email:tech@microdc.cn Tel:0086-20-86000646
Page 2 of 4