Through Hole Resistors
Product Specification
4
15
FMF
Metal Film Resistors
TEST AND REQUIRMENTS
TEST
TEST METHOD
PROCEDURE
APPRAISE
Short Time Overload
IEC 60115-1 4.13
2.5 times RCWV for 5 sec.(Not more than ±0.25%+0.05Ω
maximum overload voltage)
Voltage Proof on
Insulation
IEC 60115-1 4.7
In V-Block for 60 sec. test voltage as
above table
No Breakdown
Temperature Coefficient
Insulation Resistance
Solderability
IEC 60115-1 4.8
IEC 60115-1 4.6
IEC 60115-1 4.17
IEC 60115-1 4.30
Between -55°C to +155°C
In V-Block for 60 sec.
By Type
>1,000MΩ
245±5°C for 3±0.5 Sec.
95% Min. coverage
Solvent Resistance of
Marking
IPA for 5±0.5 Min. with ultrasonic
No deterioration of
coatings and markings
Robustness of
Terminations
IEC 60115-1 4.16
IEC 60115-1 4.39
IEC 60115-1 4.24
IEC 60115-1 4.25
IEC 60115-1 4.19
IEC 60115-1 4.18
Direct load for 10 Sec. in the direction of
the terminal leads
≥2.5Kg(24.5N)D
±1.0%+0.05Ω
±1.5%+0.05Ω
±1.5%+0.05Ω
±0.75%+0.05Ω
±0.25%+0.05Ω
Periodic-pulse Overload
Damp Heat Steady State
Endurance at 70°C
4 times RCWV 10,000 cycles (1 Sec. on,
25 Sec.off)
40±2°C,90-95% RH for 56 days, loaded
with 0.1 times RCWV
70±2°C at RCWV(or Umax., whichever
less) for 1,000 Hr.(1.5 Hr.on,0.5 Hr. off)
Temperature Cycling
➔
-55°C
➔
Room Temp.
➔
+155°C Room Temp.(5 cycles)
Resistance to Soldering
Heat
260±3°C for 10±1 Sec., immersed to a
point 3±0.5mm from the body
Accidental Overload Test IEC 60115-1 4.26
4 times RCWV for 1 Min.
No evidence of flaming
or arcing
Note:
RCWV (Rated Continuous Working Voltage ):
The DC or AC (rms) continuous working voltage corresponding to the rated power is determined by the following
formula:
V=√(P X R)
or max. working voltage whichever is less
Where
V=Continuous rated DC or
AC (rms) working voltage (V)
P=Rated power (W)
R=Resistance value (Ω)
www.yageo.com
Sep. 27, 2023 V.1