Model
Number
FDC10-12S33
FDC10-12S05
FDC10-12S12
FDC10-12S15
FDC10-12D05
FDC10-12D12
Input
Range
9 – 18 VDC
9 – 18 VDC
9 – 18 VDC
9 – 18 VDC
9 – 18 VDC
9 – 18 VDC
Output
Output
Input
Eff (8)
(%)
80
81
82
81
82
83
84
Capacitor
Voltage
3.3 VDC
5 VDC
12 VDC
15 VDC
± 5 VDC
± 12 VDC
± 15 VDC
3.3 VDC
5 VDC
12 VDC
15 VDC
± 5 VDC
± 12 VDC
± 15 VDC
3.3 VDC
5 VDC
12 VDC
15 VDC
± 5 VDC
± 12 VDC
± 15 VDC
Current
2000mA
2000mA
830mA
Current (7)
Load max(9)
6800uF
4700uF
690uF
724mA
1082mA
1064mA
1088mA
1068mA
1053mA
1041mA
362mA
534 (548mA)
519 (532mA)
523 (551mA)
548 (548mA)
520 (547mA)
520 (548mA)
183mA
260 (274mA)
253 (259mA)
258 (262mA)
267 (271mA)
254 (281mA)
260 (270mA)
670mA
470uF
± 1000mA
± 416mA
± 333mA
2000mA
2000mA
830mA
± 680uF
± 330uF
± 110uF
6800uF
4700uF
690uF
FDC10-12D15
FDC10-24S33
9 – 18 VDC
18 – 36 VDC
80
FDC10-24S05 (W)
FDC10-24S12 (W)
FDC10-24S15 (W)
FDC10-24D05 (W)
FDC10-24D12 (W)
FDC10-24D15 (W)
FDC10-48S33
FDC10-48S05 (W)
FDC10-48S12 (W)
FDC10-48S15 (W)
FDC10-48D05 (W)
FDC10-48D12 (W)
FDC10-48D15 (W)
18 – 36 (9 – 36) VDC
18 – 36 (9 – 36) VDC
18 – 36 (9 – 36) VDC
18 – 36 (9 – 36) VDC
18 – 36 (9 – 36) VDC
18 – 36 (9 – 36) VDC
36 – 75 VDC
36 – 75 (18 – 75) VDC
36 – 75 (18 – 75) VDC
36 – 75 (18 – 75) VDC
36 – 75 (18 – 75) VDC
36 – 75 (18 – 75) VDC
36 – 75 (18 – 75) VDC
82 (80)
84 (82)
84 (80)
80 (80)
84 (80)
84 (80)
79
84 (80)
86 (84)
85 (84)
82 (81)
86 (78)
84 (81)
670mA
470uF
± 1000mA
± 416mA
± 333mA
2000mA
2000mA
830mA
± 680uF
± 330uF
± 110uF
6800uF
4700uF
690uF
670mA
470uF
± 1000mA
± 416mA
± 333mA
± 680uF
± 330uF
± 110uF
Note
1. The FDC10 (W) series required a minimum 10% loading on the output to maintain specified regulation.
Operation under no-load condition will not damage these devices, however they may not meet all listed
specification
PIN CONNECTION
PIN
SINGLE
DUAL
2. Simulated source impedance of 12uH. 12uH inductor in series with +Vin.
3. The ON/OFF control is option function. There are positive logic and negative logic. The pin voltage is
referenced to negative input
To order positive logic ON-OFF control add the suffix-P (Ex: FDC10-24S05-P)
To order negative logic ON-OFF control add the suffix-N (Ex: FDC10-24S05-N)
4. BELLCORE TR-NWT-000332. Case I: 50% Stress, Temperature at 40ºC. (Ground fixed and controlled
environment)
1
2
3
4
5
6
+ INPUT
- INPUT
+ INPUT
- INPUT
+ OUTPUT
NO PIN
+ OUTPUT
COMMON
- OUTPUT
- OUTPUT
CTRL (Option) CTRL (Option)
5. M1 version is more efficient, therefore, it can be operated in a more extensive temperature range than
standard and M2 version.
6. Heat sink is optional and P/N: 7G-0020A.
7. Maximum value at nominal input voltage and full load of standard type.
8. Typical value at nominal input voltage and full load.
9. Test by minimum Vin and constant resistor load.
1.00(25.4)
0.50
(12.7)
FDC10-48S05-M1 Derating Curve
FDC10-48S05 Derating Curve
Nature convection
0.40
(10.2)
0.40
(10.2)
0.40
(10.2)
100
75
50
25
0
100
75
50
25
0
Nature convection
3
4
5
-40-25-10
0
50 60 70 80 90 100
-40-25-10 0
50 60 70 80 90 100
Bottom
View
1
AMBIENT TEMPERATURE (ºC)
AMBIENT TEMPERATURE (ºC)
2
6
FDC10-48S05-M2 Derating Curve
FDC10-48S05
Efficiency VS Output load
82
81
80
79
78
77
76
75
70
65
50
100
75
50
25
0
0.10(2.5)
0.20(5.1)
0.22(5.6)
Nature convection
1. All dimensions in Inches (mm)
2. Pin Pitch tolerance I0.014(0.35)
-40-25-10 0
50 60 70 80 90 100
1.25
1.5
1.75
0.5
1
2
AMBIENT TEMPERATURE (ºC)
OUTPUT LOAD (A)