EWS-T-SERIES Single output 1500W ~ 5000W
Ⅵ Model name
EWS 1500T-5
Nominal output voltage
Name of series
Output power
Ⅵ Features
ⅷ Compact size/3 phase-3 wire/High power
Input: 3ø200V, Power factor: 0.95
ⅷ
Output voltage programmable:
0V to nominal output voltage by external control.
Voltage adjustable range: ±20%
ⅷ Load current sharing
Open phase detector
ⅷ 3 year warranty
EWS1500T
EWS3000T
EWS5000T
ⅷ
3 year warranty
Ⅵ Specifications
1. Input voltage range 3 phases-3 wire 170 ~ 265VAC (47 ~ 63 Hz)
2. Power factor
0.95 (typ) 200VAC at full load
3. Output voltage
range
±20% (2V, 3.3V: –10 ~ +20%), 0V to nominal output voltage x 120% by external control
4. Cooling
Forced air cooling by internal fan
5. Operating ambient –10 ~ +60°C (Standard mounting)
temperature
Output derating: 70% at –10°C, 100% at 0 ~ +50°C, 70% at +60°C
6. Withstand voltage
7. Safety standard
8. Functions
Input–output: 2.5kVAC, Output–chassis: 2.5kVAC, Output–chassis: 500VAC for 1 min.
Conforms to UL and CSA
Over voltage protection, Over current protection, Thermal protection, Remote sensing
Remote on/off control, Power failure signal, Output current balancing
Ⅵ Product lineup
Model name
Nominal output voltage
Max. output current
300A
Max. DC output power
600W
UL
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
CSA
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
EWS1500T-2
EWS1500T-3.3
EWS1500T-5
EWS1500T-10
EWS1500T-12
EWS1500T-15
EWS1500T-24
EWS1500T-36
EWS1500T-48
EWS3000T-2
EWS3000T-3.3
EWS3000T-5
EWS3000T-10
EWS3000T-12
EWS3000T-15
EWS3000T-24
EWS3000T-36
EWS3000T-48
EWS5000T-2
EWS5000T-3.3
EWS5000T-5
2V
3.3V
5V
10V
12V
15V
24V
36V
48V
2V
300A
300A
150A
125A
100A
63A
42A
32A
600A
600A
600A
300A
250A
200A
125A
84A
990W
1500W
1500W
1500W
1500W
1512W
1512W
1536W
1200W
1980W
3000W
3000W
3000W
3000W
3000W
3024W
3024W
2000W
3300W
5000W
EWS1500T
3.3V
5V
10V
12V
15V
24V
36V
48V
2V
EWS3000T
EWS5000T
∆
⅜
∆
∆
63A
1000A
1000A
1000A
3.3V
5V
∆
ⅷ Request customer specification for further details of specifications, outline, characteristics, etc.
⅜ : Safety standard approved
∆ : Conforms to safety standard
Read the instruction manual before usage.
ⅷ Contact us about delivery before ordering.
19