APPLICABLE STANDARD
OPERATING
STORAGE
TEMPERATURE RANGE
-55 C TO +85 C
-10 C TO +60 C
TEMPERATURE RANGE
RELATIVE HUMIDITY: 95% MAX
(NO DEW CONDENSATION IS
PERMITTED)
OPERATING
HUMIDITY RANGE
RATING
VOLTAGE
AC 100 V
SIGNAL: 0.5A
CURRENT
SPECIFICATIONS
ITEM
TEST METHOD
REQUIREMENTS
QT AT
CONSTRUCTION
GENERAL EXAMINATION
VISUAL AND WITH MEASURING INSTRUMENT
CONFIRM VISUALLY
ACCORDING TO A DRAWING
X
X
X
X
MARKING
ELECTRIC CHARACTERISTICS
CONTACT RESISTANCE
[EIA-364-23]
100 mA
50 m MAX (*1)
MATED WITH ER8-80P-0.8SV-*H(**)
X
X
X
―
―
―
INSULATION RESISTANCE 100 V DC
[EIA-364-21]
1000 M MIN
VOLTAGE PROOF
[EIA-364-20]
300 V AC FOR 1 min
NO FLASHOVER OR BREAKDOWN
MECHANICAL CHARACTERISTICS
MECHANICAL OPERATION 100 TIMES INSERTION AND EXTRACTION
[EIA-364-09]
1) CONTACT RESISTANCE CHANGE:
15 m OR LESS
X
―
2) NO FLASHOVER OR BREAKDOWN
3) NO DAMAGE, CRACK OR LOOSENESS
OF PARTS
RANDOM VIBRATION
[EIA-364-28]
FREQUENCY: 20 TO 500 Hz
1) NO ELECTRICAL DISCONTINUITY OF
1μs OR MORE
2) NO DAMAGE, CRACK OR LOOSENESS
OF PARTS
POWER SPECTRAL DENSITY: 0.02 G2/Hz
FOR 90 min IN THREE DIRECTIONS
980 m/s2, DURATION OF PULSE: 6 ms
18TIMES TOTAL, 3 EACH DIRECTION, 3 AXIS
X
X
―
―
SHOCK
[EIA-364-27]
ENVIRONMENTAL CHARACTERISTICS
THERMAL SHOCK
[EIA-364-32]
1) CONTACT RESISTANCE CHANGE:
15 m OR LESS
TEMPERATURE(C): -55 →20 ~ 35 → 85 →20 ~ 35
TIME(min): 30 → 2 ~ 3 → 30 →2 ~ 3
X
X
―
―
UNDER 25 CYCLES
2) NO DAMAGE, CRACK OR LOOSENESS
OF PARTS
CYCLIC TEMPERATURE
AND HUMIDITY
[EIA-364-31]
@ 25 C, 90-95% RH: 120 min DWELL TIME
3) NO FLASHOVER OR BREAKDOWN
4) INSURATION RESISTANCE:1000MΩMIN
↑ ↓
120min RAMP TIME
@ 65 C, 90-95% RH: 120 min DWELL TIME
UNDER 12CYCLES
DRY HEAT
[EIA-364-17]
1) CONTACT RESISTANCE CHANGE:
EXPOSED AT 105 C, 250 HOURS
15 m OR LESS
X
X
―
―
GAS TIGHT
[EIA-364-36]
Nitric acid vapor
60min
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
CHECKED
DATE
0
APPROVED
CHECKED
DESIGNED
DRAWN
MK.EZAKI
MK.EZAKI
16.09.09
16.09.09
16.09.09
16.09.09
REMARK
(*1) THE VALUE OF CONTACT RESISTANCE INCLUDES THE BULK RESISTANCE.
TF.SUGAWARA
TF.SUGAWARA
Unless otherwise specified, refer to IEC 60512.
NOTE -- QT: QUALIFICATION TEST; AT: ASSURANCE TEST; X: APPLICATION TEST
DRAWING NO.
PART NO.
CODE NO.
ELC-369144-10-00
ER8-80S-0.8SV-5H(10)
SPECIFICATION SHEET
1/2
HIROSE ELECTRIC CO., LTD.
0
CL625-0033-0-10