Panel Mount Power Supply 5V 35W 1Phase  
ENVIRONMENT  
Ambient temperature (Operating)  
-10°C to +50°C, with operation to 70°C possible with a linear  
derating to half power from 50°C to 70°C.  
< 95%RH  
-25°C to 85°C  
3,000 Meters  
IEC60068-2-27, 30G (300m/s2)  
IEC60068-2-6, 10Hz to 150Hz @ 50m/s2 (5G peak) for all X,  
Y, Z direction  
Operating Humidity  
Ambient temperature (Storage)  
Altitude (Operating)  
Shock Test  
Vibration (Non-Operating)  
Bump  
MTBF  
IEC60068-2-29, 11ms/ 10gn  
> 700,000 hrs, as per BELL CORE STD or IEC61709  
Tested at 115Vac & 230Vac input, 100% load, 25°C ambient  
10 years (115Vac & 230Vac, 50% load and 40°C ambient).  
RoHS directive, WEEE directive  
IPX0  
Expected Cap Life Time  
Material and Parts  
Degree of protection  
Class of protection  
Pollution degree  
Class I with PE connection  
2
Output Voltage Adjust  
Inrush Current  
The 5 VDC connection is made using the "+" and "" screw  
connections. At the time of delivery, the output voltage is 5  
V DC. The output voltage can be set from 4.75 to 5.5 VDC  
on the potentiometer seen as Adjust on the front panel of  
each power supply.  
Inrush Current is the first surge current seen on the  
input side when AC input is applied to the power  
supply. It is the first pulse captured; see a typical  
picture for the inrush current as seen in the power  
supply.  
Start Up Time  
Dynamic Load  
Start up time is measured from the point AC input is  
applied and the o/p voltage reaches within 90% of its  
set value. See picture below for a typical start up time  
characteristic of a power supply.  
The Power Supply is capable of dynamic output  
voltage load change from 2% to 100% within +/-5%  
regulation limits. See picture below on the dynamic  
behavior the Power Supply.  
Rise Time  
Rise time is the time needed for o/p voltage to rise  
from 10% of its set value to 90% of its set value. See  
the picture below for a typical rise time measurement  
in a power supply.  
Hold Up Time  
Hold-up time is the duration which output voltage  
retains regulation while AC input collapses. Picture  
below is a typical hold-up time characteristic.  
www.DeltaPSU.com  
7

与EN61000-4-8相关器件

型号 品牌 描述 获取价格 数据表
EN6135B SANYO General-Purpose Switching Device Applications

获取价格

EN6137B SANYO General-Purpose Switching Device Applications

获取价格

EN6139C SANYO General-Purpose Switching Device Applications

获取价格

EN61810-1 FUJITSU POWER RELAY 2 POLE - 5A - 1.5mm contact gap

获取价格

EN62 COOPER Quick-Connect Power Distribution Blocks

获取价格

EN6235A SANYO 1/4-Duty General-Purpose LCD Display Driver

获取价格