150 Watts
xppower.com
ECP Series
•
•
•
•
•
•
•
100 W Convectionꢀcooled
150 W Forcedꢀcooled
2” x 4” Foot Print
Single Outputs from 12 V to 48 V
Builtꢀin Fan Supply
<0.5 W No Load Input Power
3 Year Warranty
Specification
Input
General
Efficiency
Isolation
• See table
Input Voltage
• 90-264 VAC (120-370 VDC),
Derate from 100% load at 100 VAC to
90% load at 90 VAC
• 47-63 Hz
• 1.5 A max at 115 VAC, 0.75 A max at
230 VAC
• 4000 VAC Input to Output
1500 VAC Input to Ground
500 VDC Output to Ground
• Primary to Secondary: 2 MOPP
Primary to Earth: 1 MOPP
• 60 kHz 10 kHz
• 300 kHrs to MIL-HDBK-217F at 25 °C, GB
Input Frequency
Input Current
Protection Level
Switching Frequency
MTBF
Inrush Current
Power Factor
• 60 A max at 230 VAC, cold start at 25 °C
• >0.95 at full load, 230 VAC
Environmental
Operating Temperature • -20 °C to +70 °C derate from 100% load
Earth Leakage Current • 230 µA at 264 VAC, 60 Hz.
No Load Input Power • <0.5 W
Input Protection
at 50 °C to 50% load at 70 °C
• Convection cooled: 100 W
Forced cooled: 150 W with 10 CFM
• Internal T3.15A/250VAC fitted in line and
neutral
Cooling
Operating Humidity
Operating Altitude
• 5% to 90% RH, non condensing
• 3000 m
Output
Storage Temperature • -40 °C to +85 °C
Output Voltage
• See tables
Shock
• IEC68-2-6, 30 g, 11 mins half sine, 3 times
in each of 6 axes
Output Voltage Trim
Initial Set Accuracy
Minimum Load
•
•
10%
1% at 50 % load
Vibration
• IEC68-2-27, 10-55 Hz, 2 g 10 mins /
sweep. 60 mins for each of 3 axes
• No minimum load requirement
• 550 ms typical
• 35 ms typical
Start Up Delay
EMC & Safety
Start Up Rise Time
Hold Up Time
Emissions
• EN55022/11, Level B conducted &
Level A radiated
• 16 ms minimum at full load and 115 VAC
Line Regulation
Load Regulation
Transient Response
•
•
0.5% max
0.5% max
Harmonic Currents
• EN61000-3-2 Class A
EN61000-3-2 Class C for load >60 W
Voltage Flicker
ESD Immunity
• EN61000-3-3
• EN61000-4-2, 8 kV air, 4 kV contact,
Perf Criteria A
• 4% maximum deviation, recovering to less
than 1% within 500 µs for 25% step load
• 1% max pk-pk, 20 MHz bandwidth,
(see note 2)
Ripple & Noise
Radiated Immunity
EFT/Burst
• EN61000-4-3, 10 V/m, Perf Criteria A
• EN61000-4-4, level 3, Perf Criteria A
Overvoltage Protection • 115% - 140% of nominal voltage on main
Surge
• EN61000-4-5, installation class 3,
Perf Criteria A
output. Recycle mains to reset.
• 110-150%
Overload Protection
Conducted Immunity
Dips & Interruptions
• EN61000-4-6, 10 V, Perf Criteria A
• EN55024, 100% 10 ms,
Short Circuit Protection • Trip and restart (hiccup)
Temperature
Coefficient
• 0.02%/°C
30%, 500 ms, 100%, 5000 ms
Perf Criteria A, A, B for high line,
A, B, B for low line at full load,
EN60601-1-2, 30% 500 ms, 60% 100 ms,
100% 10 ms, 100% 5000 ms,
Perf Criteria A, A, A, B for high line,
A, B, A, B for low line at full load
Fan Supply
• 12 V at 500 mA
Safety Approvals
• UL60950-1, IEC60950-1, EN60950-1,
ANSI/AAMI ES 60601-1, IEC60601-1,
EN60601-1