Platon Automatic Flow Controller  
DS1521  
Features:  
Fully automaꢀc ꢁow control  
No power required  
1/2” - 4” line sizes  
10:1 control range  
Fast response  
Suitable for hazardous liquids or gases  
PLATON FLOSTAT TYPE FV  
Platon Type FV Flostats automaꢀcally regulate the ꢁow of liquids or gases by using available line pressure. Once adjusted to  
the required value, ꢁow is maintained accurately at this rate independent of supply pressure ꢁuctuaꢀons or varying back  
pressure downstream of the meter. No electrical power or external ꢁow measurement input is required – the Flostat control  
system uses the available line pressure to control the balanced control valve, maintaining the ꢁow rate at the operator pre-  
set value.  
Accurate ꢁow control is vital to a wide variety of processes, for example blending and dosing applicaꢀons. By keeping the  
required ꢁuid delivery rate constant, a Flostat can ensure consistent product quality irrespecꢀve of process liquid head  
changes throughout a batch.  
Flostat Type FV Flow controllers are used in ꢁow control systems such as aircraꢂ fuel delivery systems, to prevent the  
hazard of excessive ꢁows and protect metering systems from over-speeding. On natural gas or fuel oil delivery systems to  
mulꢀple burners, Flostat units can maintain opꢀmum ꢁow rate to each burner independently.  
Available in sizes from 15mm to 100mm, all Type FV units can be fiꢃed with a ꢁow scale plate calibrated for process  
condiꢀons.  
The Flostat combines, in one body, a ꢁow measuring orifice (A) and a balanced control valve (B). With no ꢁow through the  
Flostat, the compressed spring opens the double seated valve. When ꢁow  
commences, a pressure drop P1-P2 is generated across the orifice (A). This  
pressure drop also acts on the diaphragm C, closing the valve against the  
spring force. The downstream pressure P3 has no neꢃ effect on the control  
valve posiꢀon, because the valve is double seated. At equilibrium, the spring  
force, a constant, is equal to the orifice pressure drop, making the ꢁuid ꢁow  
constant.  
The orifice ꢁow at equilibrium is adjusted by the buꢃerꢁy element, D,  
controlled by an external hand wheel. This allows ꢁow adjustment over  
typically at 10:1 range. Once set to a ꢁow rate, the Flostat maintains that  
ꢁow independent of line pressure ꢁuctuaꢀons, subject to certain minimum  
overall head loss requirements.  
General Note  
TT Electronics | Roxspur Measurement & Control Ltd  
2 Downgate Drive, Sheffield, S4 8BT, England |Ph: +44(0)114 244 2521  
TT Electronics reserves the right to make changes in product specificaꢀon without  
noꢀce or liability. All informaꢀon is subject to TT Electronics’ own data and is  
www.roxspur.com | sales@roxspur.com  
considered accurate at ꢀme of going to print.  
Issue B 7/2017 Page 1  
© TT Electronics plc  

与DS1521相关器件

型号 品牌 描述 获取价格 数据表
DS1531 TTELEC Platon B & LB Automatic Flow Controller

获取价格

DS1541 TTELEC Pre-Set Flow Controller

获取价格

DS1543 DALLAS 64k NV Timekeeping RAM

获取价格

DS1543-100 DALLAS 64k NV Timekeeping RAM

获取价格

DS1543-70 DALLAS 64k NV Timekeeping RAM

获取价格

DS1543P DALLAS 64K NV Real Time Clocks RAM

获取价格