M C C
Micro Commercial Components
TM
DL4728A thru DL4761A
ELECTRICAL CHARACTERISTICS @25°C
MCC
PART
ZENER
VOLTAGE
VZ
TEST
CURRENT
IZT
MAXIMUM
DYNAMIC
IMPEDANCE
ZZT @ IZT
MAXIMUM
REVERSE
CURRENT
IR @ VR
TEST
VOLTAGE
VR
MAXIMUM
REGULATOR
CURRENT
IZM
MAXIMUM
KNEE
TEST
CURRENT
IZK
MAXIMUM
SURGE
CURRENT
IS
NUMBER
IMPEDANCE
ZZK @ IZK
TA = 50°C
mA
VOLTS
mA
OHMS
µA
VOLTS
OHMS
mA
mA
DL4728A
3.3
3.6
3.9
4.3
4.7
5.1
5.6
6.2
6.8
7.5
8.2
9.1
10
76
69
10
10
9
100
100
50
10
10
10
10
10
10
10
10
10
10
5
1
276
252
234
217
193
178
162
146
133
121
110
100
91
400
400
1.0
1.0
1280
1260
1190
1070
970
890
810
730
660
605
550
500
454
414
380
344
304
285
250
225
205
190
170
150
135
125
115
110
95
DL4729A
DL4730A
DL4731A
DL4732A
DL4733A
DL4734A
DL4735A
DL4736A
DL4737A
DL4738A
DL4739A
DL4740A
DL4741A
DL4742A
DL4743A
DL4744A
DL4745A
DL4746A
DL4747A
DL4748A
DL4749A
DL4750A
DL4751A
DL4752A
DL4753A
DL4754A
DL4755A
DL4756A
DL4757A
DL4758A
DL4759A
DL4760A
DL4761A
1
64
1
400
1.0
58
9
1
400
1.0
53
8
1
500
1.0
49
7
1
550
1.0
45
5
2
600
1.0
41
2
3
700
1.0
37
3.5
4.0
4.5
5.0
7
4
700
1.0
34
5
700
0.5
31
6
700
0.5
28
7
700
0.5
25
7.6
8.4
9.1
9.9
11.4
12.2
13.7
15.2
16.7
18.2
20.6
22.8
25.1
27.4
29.7
32.7
35.8
38.8
42.6
47.1
51.7
56.0
700
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
11
23
8
83
700
12
21
9
5
76
700
13
19
10
14
16
20
22
23
25
35
40
45
50
60
70
80
95
110
125
150
175
5
69
700
15
17
5
61
700
16
15.5
14
5
57
700
18
5
50
750
20
12.5
11.5
10.5
9.5
8.5
7.5
7.0
6.5
6.0
5.5
5.0
4.5
4.0
3.7
3.3
5
45
750
22
5
41
750
24
5
38
750
27
5
34
750
30
5
30
1000
1000
1000
1000
1500
1500
1500
2000
2000
2000
2000
33
5
27
36
5
25
39
5
23
43
5
22
47
5
19
51
5
18
90
56
5
16
80
62
5
14
70
68
5
13
65
75
5
12
60
NOTE 1 The JEDEC type numbers shown have A 5% tolerance on nominal zener voltage.
Suffix A signifies 5% tolerance, C signifies 2% tolerance.
NOTE 2 The zener impedance is derived from the 60Hz AC voltage, which results when an AC current having an rms value equal to
10% of the DC zener current (Izt or Izk) is superimposed on Izt or Izk. Zener impedance is measured at two points to insure
a sharp knee on the breakdown curve and eliminate unstable units.
NOTE 3 The reverse surge current is measured at 25oC ambient using a 1/2 square wave or equivalent sine wave pulse 1/120 second
duration superimposed on Izt
NOTE 4 Voltage measurements to be performed 90 seconds after application of DC current.
www.mccsemi.com
2 of 3
Revision: C