CXA20 Series
S i n g l e a n d d u a l o u t p u t
DC/DC CONVERTERS 20W DC/DC Converters
1
• 4:1 input voltage range
• No minimum load on singles
• 6A on 3.3V output (@ 48Vin) at 50˚C in still air
• Wide operating temperature with overtemperature
protection
• ±10% output voltage trim
• Remote On/Off control
• Overvoltage protection
The CXA20 is a new 20W addition to the CXA family of open-frame, isolated, DC/DC
converters. The five model series features a 4:1 input voltage range of 18 to 75VDC,
making it suitable for a wide variety of communications and distributed power
applications. With its 2.0 x 1.6 inch industry standard footprint, the CXA20 provides
an easy upgrade option for new and existing Artesyn customers seeking a high-
performance, cost-effective power supply. The CXA20 is available in output voltages
of 3.3V, 5V, 12V, ±5V and ±12V. The 3.3V version delivering up to 6A is fully rated to
20W. Typical efficiency for the CXA20 is 83 percent. The CXA20 offers remote on/off,
as well as overvoltage, overtemperature and short circuit protection features.
2 YEAR WARRANTY
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
SPECIFICATIONS
OUTPUT SPECIFICATIONS
EMC CHARACTERISTICS
ETS 300 386-1 table 5
Conducted emissions
Voltage accuracy
±1.0%
EN55022, ext. cap. (Note 5)
Level A
Level B
EN55022, external filter,
VDE0878, 48V models
Line regulation
(LL to HL)
Singles/dual positives
±0.1%
±0.1%
Dual negatives
Radiated emissions
Immunity:
ESD air
ESD contact
EFT DC power
EFT signal
Radiated field enclosure EN61000-4-3 10V/m (NP)
Surges indoor signal EN61000-4-5 500V (RP)
Conducted (DC power) EN61000-4-6 10V (NP)
Conducted (signal)
Input transients
EN55022-B
See App. Note 107
Load regulation
(not incl. cross reg.)
Full load to minimum load
S3V3
Singles/dual positives
Dual negatives
±0.2%
±0.1%
±0.1%
EN61000-4-2 8kV (NP), 15kV (RP)
EN61000-4-2 6kV (NP), 8kV (RP)
EN61000-4-4 2kV (NP), 4kV (LFS)
EN61000-4-4 1kV (NP), 2kV (LFS)
Minimum load
Singles
None
10%
Duals (for imbalanced loads)
Ripple and noise
20MHz bandwidth
S3V3, S05, D05
S12, D12
All models
75mV pk-pk max.
100mV pk-pk max.
20mV rms max.
EN61000-4-6 10V (NP)
ETS 300 132-2, ETR 283
GENERAL SPECIFICATIONS
Temperature coefficient
Overvoltage protection
±0.02% /°C
Efficiency
See table
120˚C
See Application Note 107
Overtemp. shutdown
Short circuit protection
Short <20mΩ
Hiccup
Continuous
automatic recovery
Isolation voltage
Input/output test voltage
Fixed
1500VDC
400kHz
Switching frequency
Transient response
25% load step
±2.0% max. dev.,
300µs recovery to
Approvals and standards
(See Notes 6,7,8)
EN60950
UL1950 File No. E136005
within total error band
Material flammability
Weight
UL94V-0
Load cross regulation
(See Note 1)
10% load to full load,
either output
±7.0%
26g (0.92 oz)
MTBF
(Representative model
48S05 @ 48Vin)
MIL-HDBK-217F
Parts stress method
Ground Benign @ 25°C
400,000 hours
INPUT SPECIFICATIONS
Input voltage range
Input fuse
48Vin nominal
18 to 75VDC
2.0A
ENVIRONMENTAL SPECIFICATIONS
HRC recommended
48V ETS300-132
Thermal performance
Operating ambient
-40°C to +60°C,
(See Note 9)
-55°C to +125°C
temperature
Max. input rise
and fall time
5V/ms
Non-operating
ETS 300 019-2-3
Air temperature
Classes T3.1, 3.2, 3.3, 3.5
UVLO turn ON voltage
UVLO turn OFF voltage (See Note 4)
(See Note 4)
92%
86%
Low: IEC 68-2-1
High: IEC 68-2-2
Change: IEC 68-2-14
-40°C
+60°C
-40°C to +60°C
Remote ON/OFF
Logic compatibility
CMOS/TTL/Open Collector
Open circuit or >2VDC
<1.2VDC
Relative humidity
IEC 68-2-56
IEC 68-2-30
10% to 100% RH
Condensation
ON
OFF
File Name: CXA20.PDF Rev: 11 Jan 2002