CLM4102 / CLM4302
CORPORATION
AC ELECTRICAL CHARACTERISTICS
The following specifications apply for Supply Voltage = ±15V, VCM = 0, RL ≥ 100KΩ and RS = 50Ω unless otherwise noted.
Boldface limits apply for TA = TJ = TMIN to TMAX; all other limits TA = TJ = 25oC.
CLM4102
CLM4302
SYMBOL
CHARACTERISTICS
TYP
UNITS
CONDITIONS
Limit (Note 5) Limit (Note 5)
SR1
Slew Rate 1
11000
400
8000
200
6000
200
V/µs
VIN = ±10V, RL = 100Ω (Note 2)
VIN = ±100mVPP, RL = 100Ω
SSBW
PBW
tr, tf
tpd
Small Signal Bandwidth
C
L ≤ 10pF
MHz
VIN = ±4V, RL = 100Ω
Power Bandwidth
100
1.2
2.0
C
L ≤ 10pF
Rise Time
Fall Time
RL = 100Ω, CL ≤ 10pF
IN = 0.5V
1.7
1.7
ns
ns
V
RL = 100Ω, CL ≤ 10pF
IN = 0.5V
Propagation Delay Time
V
Note 1: Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. DC and AC electrical specifications do not
apply when operating the device beyond its rated operating conditions.
Note 2: Slew rate is measured with 50Ω source impedance at 25oC. Slew rate is measured between VO = +5V and -5V.
Note 3: The test circuit consists of the human body model of 120pF in series with 1500Ω.
Note 4: The maximum power dissipation is a function of TJ(max), θJA and TA. The maximum allowable power dissipation at any ambient
temperature is PD = (TJ(max) - TA)/θJA
.
Note 5: Limits are guaranteed by testing, correlation or periodic characterization.
CALOGIC CORPORATION, 237 Whitney Place, Fremont, California 94539, Telephone: 510-656-2900, FAX: 510-651-1076