125 Watts
xppower.com
CLC Series
•
•
•
•
•
•
•
125 W Forcedꢀcooled Rating
Low Profile 1.25”
Industry Standard 2”x 4” & 3”x 5” Package Sizes
12 V Fan Supply
Optional ORing Diode
<0.5 W No Load Input Power
3 Year Warranty
Specification
Input
General
Input Voltage
• 85-264 VAC (120-370 VDC),
Derate output power linearly to 90% from
90 VAC to 85 VAC
• 47-63 Hz
• 2.3 A typical at 115 VAC, full load
1.1 A typical at 230 VAC, full load
Efficiency
Isolation
• 88% typical
• 3000 VAC Input to Output, 1500 VAC
Input to Ground, 500 VDC Output to
Ground
• 65 KHz typical
• 1,245 KHrs to Telecordia SR-332
at 25 °C, GB
Input Frequency
Input Current
Switching Frequency
MTBF
Inrush Current
Power Factor
• 40 A max at 230 VAC, cold start 25 °C
• EN61000-3-2, class A
Environmental
No Load Input Power • <0.5 W
Earth Leakage Current • 80/160 µA typical 115/230 VAC 50 Hz
Operating Temperature • 0 ˚C to +70 ˚C derate linearly from +50 ˚C
300 µA at 264 VAC/60 Hz max.
at 2.5%/˚C to 50% load at +70 ˚C.
Input Protection
• Internal T5 A/250 V fuse in line
Cooling
• Forced cooled, 10 CFM
• 95% RH, non-condensing
Operating Humidity
Storage Temperature • -40 ˚C to +85 ˚C
Output
Operating Altitude
Shock
• 3000 m
• 30 g pk, half sine, 6 axes
• 2 g rms, 5 Hz to 500 kHz, 3 axes
Output Voltage
Output Voltage Trim
Initial Set Accuracy
Minimum Load
Start Up Delay
Start Up Rise Time
Hold Up Time
• 12-48 VDC (see tables)
•
•
10%
1%
Vibration
• No minimum load required
• 1 s typical
• 50 ms
EMC & Safety
Low Voltage PSU EMC • EN61204-3, high severity level as below
Emissions
• EN55022 level B conducted
EN55022 level A radiated
• 16 ms min at 230 VAC
Drift
•
•
•
0.2% after 20 min warm up
0.5% max
1%
Harmonic Currents
Voltage Flicker
Radiated Immunity
EFT/Burst
• EN61000-3-2, class A
• EN61000-3-3
• EN61000-4-3, level 3 Perf Criteria A
• EN61000-4-4, level 3 Perf Criteria A
Line Regulation
Load Regulation
Over/Undershoot
Transient Response
• 5% typical
• 4% max. deviation, recovery to within
1% in 500 µs for a 50-75-50% load
change
Surge
• EN61000-4-5, installation class 3
Perf Criteria A
Conducted Immunity
Dips & Interruptions
• EN61000-4-6, level 3 Perf Criteria A
• EN61000-4-11, 30% 10 ms, 60% 100 ms,
100% 5000 ms, Perf Criteria A, B, B
• IEC60950-1 CB report, CSA 22.2
No. 60950-1, UL60950-1, TUV EN60950-1
Ripple & Noise
• 1% pk-pk V1, 20 MHz bandwidth
Overvoltage Protection • 115-140% Vnom, recycle input to reset
Overload Protection • 110-150%
Short Circuit Protection • Continuous trip and restart (hiccup mode)
Temperature
Coefficient
Safety Approvals
• 0.05%/˚C
Equipment Protection • Class I
Class