CF5037 series
2.5V operation
= 2.375 to 2.625V, GND = 0V, Ta = −40 to +85°C unless otherwise noted.
V
CC
*1
Rating
Typ
–
Parameter
Symbol
Conditions
Unit
Min
Max
Measurement cct. 3, measured at
0V differential output (crossing
f < 350MHz
f ≥ 350MHz
45
55
%
%
Output duty cycle
Duty
40
–
60
point), Ta = 25°C, V = 2.5V
CC
5037A1: f = 120MHz
5037B×: f = 180MHz
5037C×: f = 250MHz
5037D×: f = 400MHz
5037E×: f = 600MHz
5037F×: f = 700MHz
0.25
0.25
0.25
0.25
(0.25)
(0.25)
–
–
–
–
–
V
V
Measurement cct. 3, Ta = T
differential output waveform peak-
to-peak
,
–
–
V
OPR
*2
Output swing
V
Opp
–
–
V
–
–
V
–
–
V
Output rise time
Output fall time
t
Measurement cct. 3, 20 to 80% differential output swing
Measurement cct. 3, 80 to 20% differential output swing
Measurement cct. 1, Ta = 25°C
0.3
0.3
–
0.7
0.7
2
ns
ns
ms
ns
r
t
–
f
*3
Output enable time
t
–
OE
Output disable time
t
Measurement cct. 1, Ta = 25°C
–
–
200
OD
*1. Values in parentheses ( ) are provisional only.
*2. The said values are measured by using the NPC standard jig.
*3. The built-in oscillator stop function does not operate with normal output immediately when OE goes HIGH. Instead, normal output occurs after the
oscillator startup time has elapsed.
tPER
tW
OUTN
OUT
VOD'
VOD
Hi-Z
80%
0
80%
0
OUT-OUTN
0
VOpp
20%
20%
tr
tf
VOS
OE
∆VOS
VIH
tOD
tOE
VIL
OE input waveform tr = tf 10ns
DUTY = 100t /t
(%) @ crossing point
W
PER
∆V = |V ' − V |
OD
OD
OD
Timing chart
SEIKO NPC CORPORATION —7