CF5036 series
2.5V operation
= 2.375 to 2.625V, GND = 0V, Ta = −40 to +85°C unless otherwise noted.
V
CC
Rating
Typ
–
Parameter
Symbol
Conditions
Unit
Min
45
Max
55
Measurement cct. 4, measured
at output crossing point,
f < 350MHz
f ≥ 350MHz
f < 250MHz
%
%
%
Output duty cycle 1
Output duty cycle 2
Duty1
40
–
–
60
Ta = 25°C, V = 2.5V
CC
Measurement cct. 4,
measured at 50% output swing,
45
55
Duty2
f ≥ 250MHz
40
0.2
0.2
0.2
0.2
0.2
0.2
0.2
–
–
–
60
–
%
V
Ta = 25°C, V = 2.5V
CC
5036G×: f = 80MHz
5036A×: f = 120MHz
5036B×: f = 180MHz
5036C×: f = 250MHz
5036D×: f = 400MHz
5036E×: f = 600MHz
5036F×: f = 700MHz
–
–
V
–
–
V
Measurement cct. 4,
,
Ta = T
OPR
Peak to peak of single output
waveform
*1
Output swing
V
–
–
V
Opp
–
–
V
–
–
V
–
–
V
Output rise time
Output fall time
t
Measurement cct. 4, 20 to 80% output swing
Measurement cct. 4, 80 to 20% output swing
Measurement cct. 1, Ta = 25°C
0.3
0.3
–
0.7
0.7
2
ns
ns
ms
ns
r
t
–
f
*2
Output enable time
t
–
OE
Output disable time
t
Measurement cct. 1, Ta = 25°C
–
–
200
OD
*1. The said values are measured by using the NPC standard jig.
*2. The built-in oscillator stop function does not operate with normal output immediately when OE goes HIGH. Instead, normal output occurs after the
oscillator startup time has elapsed.
tPER
tW
OUTN
OUT
80%
VOpp
Hi-Z
20%
20%
tr
tf
VIH
tOD
tOE
OE
VIL
OE input waveform tr = tf 10ns
DUTY1 = 100t /t
(%) @ crossing point
(%) @ 50% waveform
W
PER
PER
DUTY2 = 100t /t
W
Timing chart
SEIKO NPC CORPORATION —7