描述
Overvoltage protection with auto restart

C3584V 数据手册

 浏览型号C3584V的Datasheet PDF文件第1页浏览型号C3584V的Datasheet PDF文件第3页 
Euro Series  
E U R O O P T I O N S P E C I F I C AT I O N S  
OPTIONS  
INPUT  
Option “i” (inrush current limiting): A thermistor is connected in series with the  
input lines which changes its resistance from high to low when it gets hot. It does  
not reduce the current surge if the input power is interrupted for a short period of  
time not allowing the thermistor to cool down. Thermistors are fitted as standard  
to all mains input models except for 1-phase input of models > 2.5kW.  
Thermistors are available up to 45A. For higher input current an electronic inrush  
current limitation can be offered.  
Option “y” (sys-reset): This logic signal is a combination of power fail and DC-ok  
as specified for VME systems.  
Option “r” (relay): A relay instead of a logic signal is provided for failure  
indication.`  
PROGRAMMING & MONITORING  
Option “ie” electronic inrush current limiting An electronic circuit limits the inrush  
current.  
PROGRAMMING SERIES 200-5800, 6600  
By external signal, 0-10Vdc  
By external signal, 4-20mA  
By 270° potentiometer  
eu1  
eu2  
eu3  
eu4  
ei1  
ei2  
ei3  
ei4  
iso  
Option “sd” (series diode): A series diode protects the module against input  
voltage of wrong polarity (additional power losses).  
Of output voltage  
from 0 to 100%  
Option “ad” (anti-parallel diode):To avoid the power losses of a series diode a diode is  
provided with opposite polarity in parallel to the input blowing an internal or external  
fuse if the module is connected to a supply with wrong polarity.  
By 10 turn potentiometer  
By external signal, 0-10Vdc  
By external signal, 4-20mA  
By 270° potentiometer  
Of output current  
from 0 to 100%  
Option “au” (auto-ranging) For standard dual AC input models the range of  
115/230Vac is to be selected by connecting the input line to different pins on the  
connector. With auto-ranging the unit senses the input voltage and provides  
automatically the correct connection.  
By 10 turn potentiometer  
Isolating amplifier for programming  
Option “p” (power fail): A signal (logic or relay) is given if the input voltage (AC or  
DC) drops below the specified limit. In AC input units we sense the rectified input  
voltage so that a power fail alarm will not be triggered if at light loads mains  
power returns before the input capacitors are substantially discharged.  
Programming via interface RS232 or IEEE488  
MONITORING SERIES 200-5800, 6600  
By external signal, 0-10Vdc  
mu1  
mu2  
mi1  
mi2  
iso  
Of output voltage  
from 0 to 100%  
Option “r” (relay): A relay instead of a logic signal is provided for failure indication.  
By external signal, 4-20mA  
By external signal, 0-10Vdc  
By external signal, 4-20mA  
OUTPUT  
Of output current  
from 0 to 100%  
Option “dd” (decoupling diode): For redundant operation the outputs of two or  
more units are paralleled behind de-coupling diodes so that an internal fault of  
one module does not affect the operation of the others. These diodes cause power  
losses.  
Isolating amplifier for programming  
Programming via interface RS232 or IEEE488  
Option “cs” (active current sharing): An additional control circuit provides active  
current sharing via an interconnecting wire between converters that operate in  
parallel. Active current sharing should be used for multi-output units operating in  
parallel.  
CHARGER PROGRAMMING (ALL SERIES)  
Temperature compensated charging voltage(sensor not included)  
Not interchangeable due to fixed  
tc  
ts1  
ts2  
ch1  
ch2  
ch3  
resistor values  
Temperature sensor  
Option “csi” (current sharing interrupt): Option “csi” will effect the removal of the  
“cs” signal. Should there be an instance where a unit is not supplying the load,  
then the effect of its “cs” signal is removed, and the load voltage is unaffected by  
this condition.  
Interchangeable, IC controlled  
Automatic selection of charging characteristic (float / equalize  
charge) with timer  
Additionally: Manual selection of charging characteristic  
Option “h1” (inhibit): A terminal connected to the negative input line also shuts off the  
converter. This can also be used in conjunction with a thermal trip which shuts the unit  
down.  
Additionally: Boost charge operation (manually activated with  
time delayed return to normal operation)  
Option “h2” (inhibit): Operation of the unit is inhibited if a voltage signal  
(5V/10mA) is applied in reference to the negative line of the (main) output.  
Option “rco” (reducing current limiting at over temperature) A circuit reduces the  
current limiting level at higher temperature (to be specified).  
Option “d” (DC-ok, one output): A logic signal is given if the output voltage (main  
output in multi-output systems) is below the specified limit.  
Option “m” (DC-ok, all outputs): In multi-output systems a logic signal is provided  
if the voltage of any output is below the specified limit.  
Option “ac” (AC ok) A logic signal connected to relay contacts is given if the  
output voltage of an inverter is below the specified limit.  
Doc. No. PBC9 Rev.C 28-4-11  
Powering Progress – www.powerbox.com.au  

与C3584V相关器件

型号 品牌 描述 获取价格 数据表
C3584Z POWERBOX Overvoltage protection with auto restart

获取价格

C3585 POWERBOX Overvoltage protection with auto restart

获取价格

C3585V POWERBOX Overvoltage protection with auto restart

获取价格

C3585Z POWERBOX Overvoltage protection with auto restart

获取价格

C3586 POWERBOX Overvoltage protection with auto restart

获取价格

C3586V POWERBOX Overvoltage protection with auto restart

获取价格