Effective August 2017
Supersedes August 2012
Technical Data 4415
C310FC
3.6 mm x 10 mm Fast-acting, axial-leaded ceramic tube fuses
HALOGEN
Agency information
• cURus Approval: File E19180 Guide JDYX2/YX8
HF
Pb
• TUV Approval: File No: J 50217156
• CQC: CQC12012069004
• KC: SU05030-12001A
FREE
Environmental data
• Terminal Strength: MIL-STD-202G Method 211A. Test Condition
A
• Thermal Shock: MIL-STD-202G,Method 107G
(Test Condition 5 cycles -40 °C to 85 °C)
• Resistance to Moisture: MIL-STD-202G, Method 106, Humidity
(90~98%RH), Heat (+65 °C)
• Vibration: MIL-STD-202G, Method 201A (10~55 Hz) Condition A
• Salt Spray: MIL-STD-202G, Method 101D, Test Condition B
• Solderability: J-STD-002C, Test Method C1
Product features
• Single cap, axial leaded, fast-acting fuse
• 3.6 x 10mm physical size
• Ceramic tube, nickel-plated brass endcap
construction
• Tinned copper axial leads
Ordering
• Specify packaging, product and option code
(e.g., C310FC-2-TR1)
• Designed to IEC60127-3, Sheet 3
Electrical Characteristics
1.5I
Min
2.1I
2.75I
Min
4I
n
10I
n
Max
n
n
n
Max
Amp Rating
800mA~3.15A 1hour 30min 10ms 3sec 3ms 300ms 20ms
Max
Min
Max
Speciꢀcations
Voltage Interrupting Rating Typical Cold
Catalog
Typical
Max. Voltage
Agency Information
2
2
@ 250 Vac (A)
Number
Rating Vac
250
Resistance (mΩ)*
TUV
X
X
X
X
CQC KC
Drop (mV)*** cURus
MeltingI t (A s)**
C310FC-800mA-R
C310FC-1.6A-R
C310FC-2A-R
C310FC-3.15A-R
35
35
35
35
70
34.5
26
0.56
2.2
3.8
180
120
100
100
X
X
X
X
250
250
250
X
X
X
X
X
X
15
13.3
* Typical Cold Resistance (Measured at <_10% of rated current).
** Typical Melting I2t (Tested at 10l ).
n
*** Maximum Voltage Drop (Voltage drop was measured at +25 °C ambient temperature at rated current).