Data Sheet
100VAC Input/−12VDC (300mA) Output
Non-Isolated AC/DC Converter
BP5061
Absolute Maximum Ratings
Dimensions (Unit : mm)
9.1MAX.
Parameter
Input voltage
Symbol
Vi
Limits
−170
Unit
V
35.0MAX.
Output current
Io
300
mApk
kV
ESD endurance
Vsurge
Topr
Tstg
2
1
3
5
7
10
1
Operating temperature range
Storage temperature range
−25 to +80
−25 to +105
°C
°C
0.25±0.0
5
0.5±0.1
5.08±0.2
2.54�11=27.94
1.3±0.2
7.62 0.3
±
4.85MAX.
4.25MAX.
3.6MAX
Electrical Characteristics
Parameter
Input voltage range
Output voltage
Output current
Line regulation
Load regulation
Output ripple voltage
Power conversion efficiency
Symbol Min.
Typ.
−141
−12.0
−
0.04
0.05
0.07
78
Max.
−170
−13.0
300
0.15
0.15
0.15
−
Conditions
DC (80 to 120VAC)
Vi=−141V, Io=200mA
Vi=−141V
Vi=−113V to −170V, Io=200mA
Vi=−141V, Io=0 to 200mA
Unit
V
V
mA
V
V
Derating Curve
−113
−11.0
0
Vi
Vo
Io
Derating Curve
350
300
250
200
∗1
−
−
−
70
Vr
Vl
Vp
η
150
Operation Range
100
50
0
Vp-p
%
Vi=−141V, Io=200mA
Vi=−141V, Io=300mA
∗2
-30 -20 -10
0 10 20 30 40 50 60 70 80 90
Ambient Temperature Ta(°C)
∗1 Maximum output current varies depending on ambient temperature ; please refer to derating curve.
∗2 Spike noise is not included in output ripple voltage.
Conversion Efficiency
Conversion Efficiency
(Ta=25°C, Vi=−141V)
100
Application Circuit
90
80
70
60
50
40
30
20
10
0
Pin No.
1
2
3
4
5
6
7
8
9
Function
Output terminal Vo(−12V)
Not used
Coil connect
Not used
Coil connect
Not used
COMMON
Not used
Not used
N.C.
Not used
Input voltage Vi(−141VDC
)
BP5061
Please note that pin No.12
side is input.
0
50 100 150 200 250 300
Output Current Io(mA)
10
11
12
12 10
7
5
3
1
FUSE
R1
Output
−12V
1A
D1
10Ω1/4W
Load Regulation
L1
1mH
Load Regulation
(Ta=25°C, Vi=−141V)
C2
C3
Input
AC100V
50Hz/60Hz
−
+
−
+
ZNR
220V
C1
13.0
0.1µF
100µF/50V
33µF/200V
12.5
12.0
11.5
11.0
Be sure to use fuse for safety.
Please verify operation and characteristics in the customer's circuit before actual usage.
Ensure that the load current does not exceed the maximum rating.
0
50 100 150 200 250 300
Output Current Io(mA)
External Component Specifications
FUSE: Fuse
Use a quick-acting fuse of 1A
Surface Temperature Increase
C1: Input smoothing
capacitor
Capacitance : 22 to 100µF Rated voltage : 200V or higher
Ripple current is 0.13Arms or greater.
Surface Temperature Increase
(Ta=25°C, Vi=−141V)
50
45
40
35
30
25
20
15
10
5
Capacitance : 0.1 to 0.22µF Rated voltage : 200V or higher
Use a film or ceramic capacitor. Evaluate under actual
conditions.
C2: Noise reduction
capacitor
Capacitance : 100 to 470µF Rated voltage : 25V or higher,
ECR is 0.4Ω max. Ripple current is 0.25Arms or higher.
Evaluate under actual operating conditions.
C3: Output smoothing
capacitor
0
0
50 100 150 200 250 300 350
Output Current Io(mA)
D1: Rectifier diode
In the absolute maximum ratings, the reverse peak voltage should be
400V or higher, the average rectifying current should be 1A or higher,
and the peak surge current should be 20A or higher.
(Full-wave rectification can be used.)
Coil for switching regulator. The inductance should be 1mH,
the rated direct current should be 0.6A or greater in order to prevent
overheating or abnormal oscillation.
L1: Choke coil
10 to 22Ω 1/4W
Determine the ideal value through actual testing.
R1: Noise reduction
resistor
A varistor is required to protect against lightning surges and
static electricity.
ZNR: Varistor
www.rohm.com
©2010 ROHM Co., Ltd. All rights reserved.
2010.01 - Rev.A
1/1