Reference Only
Spec. No. JENF243A-9122P-01
P.3/11
(*1)
Standard Testing Conditions
Unless otherwise specified
In case of doubt
Temperature : Ordinary Temp. (15 °C to 35 °C )
Temperature : 20°C±2 °C
Humidity : Ordinary Humidity (25%(RH) to 85%(RH))
Humidity : 60%(RH) to 70%(RH)
Atmospheric pressure : 86kPa to 106kPa
Rated current
at 85°C
(*2)In case of Rated current is more than 1A,
Rated Current is derated as right figure
depending on the operating temperature.
Rated current
at 125°C
0
85
125
Operating Temperature (°C)
4.Style and Dimensions
1.6±0.15
0.8±0.15
■ Equivalent Circuit
T
0.4±0.2
Resistance element becomes
dominant at high frequencies.
(
)
: Electrode
(in mm)
■ Unit Mass (Typical value)
T
0.5±0.15
0.6±0.15
0.8±0.15
BLM18SG***TZ1D
BLM18*****TZ1D
0.004g
BLM18KG***TZ1D
BLM18SN***TZ1D
BLM18*****SZ1D
BLM18*****SZ1D
0.005g
5.Marking
No marking.
6.Specifications
6-1.Electrical Performance
No. Item
Specification
Meet item 3.
Test Method
6-1-1 Impedance
Measuring Frequency : 100MHz±1MHz
Measuring Equipment : KEYSIGHT 4991A or the equivalent
Test Fixture : KEYSIGHT 16192A or the equivalent
Measuring Equipment : Digital multi meter
6-1-2 DC Resistance
Meet item 3.
For BLM18SN
Measuring Equipment : YOKOGAWA 755611 or the equivalent
Test Fixture : KEYSIGHT 16044A or the equivalent
*Except resistance of the Substrate and Wire
MURATA MFG.CO., LTD.