●Magnetic, Electrical Characteristics
BU52001GUL (Unless otherwise specified, VDD=3.0V, Ta=25℃)
LIMIT
TYP MAX
PARAMETERS
Power Supply Voltage
SYMBOL
VDD
UNIT
V
CONDITIONS
MIN
2.4
3.0
3.3
BopS
BopN
BrpS
BrpN
BhysS
BhysN
-
3.7
-3.7
2.9
-2.9
0.8
5.5
-
-
-0.8
-
-
Operate Point
Release Point
mT
-5.5
0.8
-
-
-
mT
Hysteresis
mT
ms
V
0.8
Period
Tp
-
50
-
100
-
15
※
VDD
-0.4
BrpN<B<BrpS
OUT =-1.0mA
B<BopN,BopS<B
IOUT =+1.0mA
Output High Voltage
VOH
I
15
※
Output Low Voltage
VOL
-
-
-
-
-
0.4
12
-
V
Supply Current
IDD(AVG)
IDD (EN)
IDD (DIS)
8
μA
mA
μA
Average
Supply Current During Startup Time
4.7
3.8
During Startup Time Value
During Standby Time Value
Supply CurrentDuring Standby Time
-
※15 B = Magnetic flux density
1mT=10Gauss
Positive (“+”) polarity flux is defined as the magnetic flux from south pole which is direct toward to the branded face of the sensor.
After applying power supply, it takes one cycle of period (TP) to become definite output.
Radiation hardiness is not designed.
BU52015GUL (Unless otherwise specified, VDD=1.80V, Ta=25℃)
LIMIT
TYP MAX
PARAMETERS
Power Supply Voltage
SYMBOL
VDD
UNIT
V
CONDITIONS
MIN
1.65
1.80
3.30
BopS
BopN
BrpS
-
3.0
-3.0
2.1
5.0
Operate Point
Release Point
mT
mT
-5.0
-
0.6
-
BrpN
-
-
-
-2.1
0.9
-0.6
BhysS
BhysN
-
-
Hysteresis
Period
mT
ms
0.9
Tp
-
50
100
16
※
OUT1: BrpN<B<BrpS
OUT2: B<BopN, BopS<B
IOUT = -0.5mA
VDD
-0.2
Output High Voltage
Output Low Voltage
VOH
-
-
V
V
16
※
OUT1: B<BopN, BopS<B
OUT2: BrpN<B<BrpS
IOUT = +0.5mA
VOL
-
-
0.2
Supply Current 1
IDD1(AVG)
IDD1(EN)
-
-
5
8
-
μA
V
DD=1.8V, Average
VDD=1.8V,
Supply Current During Startup Time 1
2.8
mA
During Startup Time Value
VDD=1.8V,
Supply CurrentDuring Standby Time 1
Supply Current 2
IDD1(DIS)
IDD2(AVG)
IDD2(EN)
-
-
-
1.8
8
-
12
-
μA
μA
During Standby Time Value
VDD=2.7V, Average
VDD=2.7V,
Supply Current During Startup Time 2
4.5
mA
During Startup Time Value
VDD=2.7V,
Supply CurrentDuring Standby Time 2
IDD2(DIS)
-
4.0
-
μA
During Standby Time Value
※16 B = Magnetic flux density
1mT=10Gauss
Positive (“+”) polarity flux is defined as the magnetic flux from south pole which is direct toward to the branded face of the sensor.
After applying power supply, it takes one cycle of period (TP) to become definite output.
Radiation hardiness is not designed.
www.rohm.com
2010.01 - Rev.C