SAW Components
SAW RF filter
Data sheet
B3948
868.60 MHz
Characteristics
Temperature range for specification:
Terminating source impedance:
Terminating load impedance:
T
= –40 ˚C to +95 ˚C
ZS = 50 Ω and matching network
ZL = 50 Ω and matching network
min.
typ.
max.
@ 25 ˚C
868.60
Center frequency
fC
—
—
MHz
Minimum insertion attenuation
incl. loss in matching elements (QL = 90)
excl. loss in matching elements
αmin
—
—
2.4
2.1
3.2
2.9
dB
dB
Pass band (relative to αmin
)
868.00 ... 869.20 MHz
—
0.9
3.0
dB
Relative attenuation (relative to αmin
)
αrel
10.00 ... 820.00 MHz
820.00 ... 862.00 MHz
862.00 ... 863.60 MHz
863.60 ... 866.60 MHz
866.60 ... 867.20 MHz
870.40 ... 871.40 MHz
871.40 ... 875.00 MHz
875.00 ... 890.00 MHz
890.00 ... 950.00 MHz
950.00 ... 1500.00 MHz
1500.00 ... 2500.00 MHz
47
38
32
21
10
10
20
22
38
50
48
52
43
38
28
25
15
24
27
43
55
53
—
—
—
—
—
—
—
—
—
—
—
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
Impedance for pass band matching1)
Input: ZIN = RIN || CIN
—
—
325 || 1.2
325 || 1.2
—
—
Ω || pF
Ω || pF
Output: ZOUT = ROUT || COUT
1)
Impedance for passband matching bases on an ideal, perfect matching of the SAW filter to source- and to load
impedance (here 50 Ohm). After removal of the SAW filter the input impedance of the input and output match-
ing network is calculated. The conjugate complex value of these characteristic impedances are the input and
output impedances for flat passband. For more details we refer to EPCOS application note #18.
Please read cautions and warnings and
important notes at the end of this document.
3