SAW Components Low-loss Filter 868,30 MHz

B39871-B3762-Z810 技术参数

是否Rohs认证: 符合生命周期:Obsolete
Reach Compliance Code:compliant风险等级:5.56
Is Samacsys:N中心频率或截止频率 (fo/fc):868.3 MHz
滤波器类型:SAW FILTER高度:1.8 mm
输入阻抗:270 OHM//1 pF最大插入损耗:3.8 dB
JESD-609代码:e4长度:3.8 mm
安装类型:SURFACE MOUNT功能数量:1
最高工作温度:120 °C最低工作温度:-45 °C
输出阻抗:270 OHM//1 pF Ω物理尺寸:L3.8XB3.8XH1.8 (mm)/L0.15XB0.15XH0.071 (inch)
端子面层:GOLD OVER NICKEL宽度:3.8 mm
Base Number Matches:1

B39871-B3762-Z810 数据手册

 浏览型号B39871-B3762-Z810的Datasheet PDF文件第1页浏览型号B39871-B3762-Z810的Datasheet PDF文件第2页浏览型号B39871-B3762-Z810的Datasheet PDF文件第3页浏览型号B39871-B3762-Z810的Datasheet PDF文件第5页浏览型号B39871-B3762-Z810的Datasheet PDF文件第6页 
SAW Components  
Low-loss Filter  
Data Sheet  
B3762  
868,30 MHz  
Matching network to 50 (element values depend on pcb layout and equivalent circuit)  
Cp1 = 2,2 pF  
Ls2 = 18 nH  
Ls3 = 18 nH  
Cp4 = 2,2 pF  
Minimising the crosstalk  
For a good ultimate rejection a low crosstalk is necessary. Low crosstalk can be realised with  
a good RF layout. The major crosstalk mechanism is caused by the “ground-loop” problem.  
Grounding loops are created if input-and output transducer GND are connected on the top-side  
of the PCB and fed to the system grounding plane by a common via hole. To avoid the common  
ground path, the ground pin of the input- and output transducer are fed to the system ground  
plane (bottom PCB plane) by their own via hole. The transducers’ grounding pins should be  
isolated from the upper grounding plane.  
A common GND inductivity of 0.5nH degrades the ultimate rejection (crosstalk) by 20dB.  
The optimised PCB layout, including matching network for transformation to 50 Ohm, is shown  
here. In this PCB layout the grounding loops are minimised to realise good ultimate rejection.  
Optimised PCB layout for SAW filters in QCC8B package, pinning 1,5 (top side, scale 1:1)  
The bottom side is a copper plane (system ground area). The input and output grounding pins  
are isolated and connected to the common ground by separated via holes.  
For good contact of the upper grounding area with the lower side it is necessary to place  
enough via holes.  
4
Feb 27, 2004  

与B39871-B3762-Z810相关器件

型号 品牌 描述 获取价格 数据表
B39871B3773Z810 EPCOS SAW filter 868.95 MHz

获取价格

B39871B3776Z810 EPCOS SAW filter Short range devices

获取价格

B39871B3903U510 EPCOS SAW RF filter Short range devices

获取价格

B39871B3941H110 TDK SAW filter

获取价格

B39871B3948H110 TDK SAW Components SAW RF filter Short range devices

获取价格

B39871B4316P810 TDK SAW filter

获取价格