Model Selection Guide
Input
Output
Current
(mA, Max) (mA, Min)
Fuse Rating
Slow-Blow
(mA)
Model
Number
Efficiency
(%, Typ)
Voltage (VDC)
Current (mA)
Voltage
(VDC)
Current
Nominal
Range
Full-Load No-Load
B1001ERW
B1002ERW
B1003ERW
B1004ERW
B1005ERW
B1006ERW
B1011ERW
B1012ERW
B1013ERW
B1014ERW
B1015ERW
B1016ERW
B1021ERW
B1022ERW
B1023ERW
B1024ERW
B1025ERW
B1026ERW
12
12
12
12
12
12
24
24
24
24
24
24
48
48
48
48
48
48
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
36.0 - 75.0
36.0 - 75.0
36.0 - 75.0
36.0 - 75.0
36.0 - 75.0
36.0 - 75.0
1,111
1,068
1,041
1,157
1,082
1,041
555
534
520
563
508
496
257
242
242
264
245
245
25
25
25
25
25
25
8
8
8
8
8
8
5
5
5
5
5
5
5
12
15
5
12
15
5
12
15
5
12
15
5
2,000
832
660
1,000
416
333
2,000
832
660
1,000
416
333
2,000
830
670
1,000
416
333
200
83
66
100
41
33
200
83
66
100
41
33
200
83
66
100
41
33
75
78
80
72
77
80
75
78
80
74
82
84
81
86
86
79
85
85
3,000
3,000
3,000
3,000
3,000
3,000
1,500
1,500
1,500
1,500
1,500
1,500
750
12
15
5
12
15
750
750
750
750
750
Notes:
Derating Curve
1. Transient recovery is measured to within a 1% error band for a load
step change of 75% to 100%.
2. Output load regulation is specified for a load change of 25% to
100%.
3. When measuring output ripple, it is recommended that an external
ceramic capacitor (approx approx 1 µF to 10 µF) be placed from the
+Vout pin to the -Vout pin for single output units and from each output
to common for dual output units.
4. These units should not be operated with a load under 10% of full load.
Operation at no-load may cause damage to the unit.
5. These converters are specified for operation without external com-
ponents. However, in some applications the addition of input/ouput
capacitors will enhance stability and reduce output ripple. Recom-
mended capacitor values are:
Input
Capacitor
Output
Capacitor
Vin
12 VDC
24 VDC
48 VDC
100 µF
100 µF
100 µF
100 µF per 1A of Iout
100 µF per 1A of Iout
100 µF per 1A of Iout
For applications requiring very low output noise levels, a simple LC
filter should be effective.
Mechanical Dimensions
6. Dual output units may be connected to provide a 10V, 24V or 30 VDC
output. To do this, connect the load across the positive (+Vout) and
negative (-Vout) outputs and float the output common.
7. It is recommended that a fuse be used on the input of a power supply
for protection. See the Model Selection table above for the correct
rating.
Capacitive
Load
Pin Connections
Pin
1
Single
+Vin
Dual
+Vin
Single Output
(µF Max)
2
3
4
5
-Vin
-Vin
400
+Vout
No Pin
-Vout
+Vout
Common
-Vout
Dual Output
(µF Max)
200
Mechanical Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = 0.01 ( 0.25)
MicroPower Direct
•
www.micropowerdirect.com
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
FAX: (781) 344-8481
•
E-Mail: sales@micropowerdirect.com