B-NXT-1W Series  
Output Specifications  
Parameter  
Rated Power  
Conditions  
TA=-40°C to 85°C  
Min.  
Typ.  
Max.  
1.0  
Units  
W
Voltage Set Point  
Line regulation  
See tolerance envelope  
High VIN to low VIN  
1.0  
10  
1.2  
14  
%%  
%
10% load to rated load, 0303& 0503  
10% load to rated load, 0505& 1205  
10% load to rated load, 0506  
12.8  
9.2  
8.3  
6.8  
6.3  
40  
15  
%
10  
%
Load regulation1  
10% load to rated load, 0509 & 1209  
10% load to rated load, 0512& 1212  
10% load to rated load, 0515& 1215  
BW=DC to 20MHz, 3.3V output types, 0305 & 0505  
BW=DC to 20MHz, 3.3V output types,0505 & 1205  
BW=DC to 20MHz, 0506  
9.0  
7.5  
7.0  
60  
%
%
%
mV p-p  
mV p-p  
mV p-p  
mV p-p  
mV p-p  
mV p-p  
62  
85  
103  
49  
170  
75  
RippleNoise  
BW=DC to 20MHz, 0509& 1209  
BW=DC to 20MHz, 0512& 1212  
BW=DC to 20MHz, 0515& 1215  
39  
65  
38  
76  
Note:112V input types have typically 3% less load regulation change.  
Temperature Characteristics  
Parameter  
Specification  
Storage  
Conditions  
All output types  
Min.  
-40  
Typ.  
Max.  
85  
Units  
-55  
125  
0305, 0309, 0315  
0303, 0312, 0503, 0505, 0509, 0512C, 0515  
0505, 1205  
25  
30  
43  
40  
Case temperature  
rise above ambient  
1209, 1212, 1215  
Cooling  
Free air convection  
Technical notes  
ISOLATION VOLTAGE  
Hi Pot TestFlash TestedWithstand VoltageProof VoltageDielectric Withstand Voltage'&'Isolation Test Voltageare all terms that relate to the same thing, a test voltage, applied for a specified  
time, across a component designed to provide electrical isolation, to verify the integrity of that isolation.  
Professional Power Module B-NXT series of DC/DC converters are all 100% production tested at their stated isolation voltage. This is 1kVDC for 1 second.  
A question commonly asked is, What is the continuous voltage that can be applied across the part in normal operation?”  
For a part holding no specific agency approvals, such as the B-NXT series, both input and output should normally be maintained within SELV limits i.e. less than 42.4V peak, or 60VDC. The isolation test voltage  
represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The part could be expected to function correctly with several hundred volts  
offset applied continuously across the isolation barrier; but then the circuitry on both sides of the barrier must be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a  
barrier between these circuits and any user-accessible circuitry according to safety standard requirements.  
REPEATED HIGH-VOLTAGE ISOLATION TESTING  
It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials, construction and environment.  
The B-NXT series has toroidal isolation transformers, with no additional insulation between primary and secondary windings of enameled wire. While parts can be expected to withstand several times the stated  
test voltage, the isolation capability does depend on the wire insulation. Any material, including this enamel (typically polyurethane) is susceptible to eventual chemical degradation when subject to very high  
applied voltages thus implying that the number of tests should be strictly limited. We therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be  
reduced by 20% from specified test voltage.  
This consideration equally applies to agency recognized parts rated for better than functional isolation where the wire enamel insulation is always supplemented by a further  
insulation system of physical spacing or barriers.  
Temperature derating graph  
http://www.microdc.cn  
Technical Enquiries-Email:tech@microdc.cn Tel:0086-20-86000646  
Page 2 of 6  

与B0309NXT-1W相关器件

型号 品牌 描述 获取价格 数据表
B0309XD-1W25 MICRODC Isolated 1.25W Single Output DC-DC Converters

获取价格

B0309XT-1W MICRODC 1W, FIXED INPUT, ISOLATED SINGLE OUTPUT SMD DC-DC CONVERTER

获取价格

B0310-A COILCRAFT SMPS Transformer, 60W

获取价格

B0310-AL COILCRAFT Planar Transformers

获取价格

B0310-ALB COILCRAFT SMPS Transformer, 60W, ROHS COMPLIANT

获取价格

B0310J50100A00 ANAREN Ultra Low Profile 0805 Balun

获取价格