OUTLINE DIMENSIONS & PIN CONNECTIONS
MECHANICAL DIMENSIONS
RECOMMENDED FOOTPRINT
B_S Series
B_D Series
B_S Series
1
2
3
4
(Front View)
(Front View)
4.10 [0.161]
5.08 [0.200]
B_D Series
∅1.00 [0.039]
4.10 [0.161]
7
5
4
7.62 [0.300]
12.70[0.500]
7.62[0.300]
1
11.60[0.461]
0.50[0.020]
0.90[0.035]
6.00[0.236]
1
4
Note:grid 2.54*2.54mm .
(Bottom View)
1
2
3
4
TUBE OUTLINE DIMENSIONS
(Bottom View)
7
5
B_D Series
B_S Series
∅1.00 [0.039]
0.50[0.020]
9.60[0.378]
12.50[0.492]
FOOTPRINT DETAILS
FOOTPRINT DETAILS
B_S
GND
Vin
Pin
1
B_D
Pin
1
GND
4
Vin
2
+Vo
5
3
0V
3.50[0.138]
7
0V
4
+Vo
4.90[0.193]
Note:
Unit :mm[inch]
General tolerances: ± 0.50mm[± 0.020inch]
L=530mm[20.866inch] Devices per tube: 43pcs(B_S) 40pcs(B_D)
L=220mm[8.661inch] Devices per tube: 17pcs(B_S) 16pcs(B_D)
Note:
Unit:mm[inch]
Pin section tolerances:± 0.10mm[± 0.004inch]
General tolerances:± 0.25mm[± 0.010inch]
Short tube inner packaging dimensions: L*W*H=255*170*80mm;
Short tube outer packaging dimensions(with six inner packaging boxes):
L*W*H=375*280*270mm;
Long tube inner packaging dimensions: L*W*H=580*200*100mm;
Long tube outer packaging dimensions(with two inner packaging boxes):
L*W*H=600*215*220mm;
Long tube outer packaging dimensions(with three inner packaging boxes)
L*W*H=600*215*325mm.
:
Note:
1. Operation under minimum load will not damage the converter; However, they may not meet all specification listed, and that will reduce the
life of product.
2. All specifications measured at Ta=25°C, humidity<75%, nominal input voltage and rated output load unless otherwise specified.
3. Only typical models listed, other models may be different, please contact our technical person for more details.
4. In this datasheet, all the test methods of indications are based on corporate standards.
The copyright and authority for the interpretation of the products are reserved by MORNSUN
Specifications subject to change without notice.
B_S(D)-W2 B/2-2012 Page 3 of 3