AZ9431
RELAY ORDERING DATA
STANDARD RELAYS
COIL SPECIFICATIONS
ORDER NUMBER*
Nominal
Coil
VDC
Max.
Continuous
VDC
Coil
Resistance
10ꢀ
Must
Operate
VDC
Medium Duty 10 Amp contact)
Heavy duty (15 Amp contact)
Unsealed Sealed
Unsealed
Sealed
5
10.9
13.0
19.5
26.0
39.1
52.1
104.3
70
3.8
AZ9431–1C–5D
AZ9431–1C–5DE
AZ9431–1CH–5D AZ9431–1CH–5DE
AZ9431–1CH–6D AZ9431–1CH–6DE
AZ9431–1CH–9D AZ9431–1CH–9DE
AZ9431–1CH–12D AZ9431–1CH–12DE
AZ9431–1CH–18D AZ9431–1CH–18DE
AZ9431–1CH–24D AZ9431–1CH–24DE
AZ9431–1CH–48D AZ9431–1CH–48DE
6
100
4.5
AZ9431–1C–6D
AZ9431–1C–9D
AZ9431–1C–12D
AZ9431-1C-18D
AZ9431–1C–24D
AZ9431–1C–48D
AZ9431–1C–6DE
AZ9431–1C–9DE
AZ9431–1C–12DE
AZ9431-1C-18DE
AZ9431–1C–24DE
AZ9431–1C–48DE
9
225
6.8
12
18
24
48
400
9.0
900
13.5
18.0
36.0
1,600
6,400
*Substitute “1A” or “1AH” in place of “1C” or “1CH” to indicate 1 Form A. Add suffix “F” for Class F version. Add “H” to AZ9431 for 6 kV version.
MECHANICAL DATA
PC Board Layout
.134
[3.40]
.762 Max
[19.25]
.612 Max
[15.25]
.059
[1.49]
.236[6.0]
.472
12.00
.602 Max
[15.29]
.185
[4.70]
.480
[12.20]
.012
[.30]
.559
[14.20]
VIEWED TOWARD TERMINALS
Wiring Diagram
.014
[.36]
4
.016
3
3
2
2
1
1
4 x .032
[0.8]
.039
[1.0]
5
4
5
FORM
C
FORM
VIEWED TOWARD TERMINALS
Dimensions in inches with metric equivalents in parentheses. Tolerance:
.010"
5/26/05W