AZ2110/AZ2120
RELAY ORDERING DATA
STANDARD RELAYS: UL 508 Group A; UL 873 Version
COIL SPECIFICATIONS
ORDER NUMBER*
Nominal
Coil
Max.
Continuous
VDC
Coil
Resistance
±10%
Must
Operate
VDC
Form A (SPST)
Form C (SPDT)
VDC
5
6
9
12
15
18
24
48
70
110
7.3
8.9
27
40
97
155
256
3.75
4.5
6.75
9.0
11.25
13.5
18.0
36.0
52.5
82.5
AZ2110–1A–5D
AZ2110–1A–6D
AZ2110–1A–9D
AZ2110–1A–12D AZ2110–1C–12D
AZ2110–1A–15D AZ2110–1C–15D
AZ2110–1A–18D AZ2110–1C–18D
AZ2110–1A–24D AZ2110–1C–24D
AZ2110–1A–48D AZ2110–1C–48D
AZ2110–1A–70D AZ2110–1C–70D
AZ2110–1A–110D AZ2110–1C–110D
AZ2110–1C–5D
AZ2110–1C–6D
AZ2110–1C–9D
13.9
17.5
22.5
27.4
36.1
68.4
104.4
163.2
380
660
2,560
5,500
13,450
STANDARD RELAYS: UL 508 Group B Version
COIL SPECIFICATIONS
ORDER NUMBER*
5
6
9
12
15
18
24
48
70
110
7.3
8.9
27
40
97
155
256
380
660
3.75
4.5
6.75
9.0
11.25
13.5
18.0
36.0
52.5
82.5
AZ2111–1A–5D
AZ2111–1A–6D
AZ2111–1A–9D
AZ2111–1A–12D AZ2111–1C–12D
AZ2111–1A–15D AZ2111–1C–15D
AZ2111–1A–18D AZ2111–1C–18D
AZ2111–1A–24D AZ2111–1C–24D
AZ2111–1A–48D AZ2111–1C–48D
AZ2111–1A–70D AZ2111–1C–70D
AZ2111–1A–110D AZ2111–1C–110D
AZ2111–1C–5D
AZ2111–1C–6D
AZ2111–1C–9D
13.9
17.5
22.5
27.4
36.1
68.4
104.4
163.2
2,560
5,500
13,450
* Substitute “1B” in place of the “1A” to indicate 1 Form B contact. To indicate Class F version, add suffix “F”.
For quick connect terminals on contacts substitute “2120” or “2121” in place of “2110” or “2111”. Add suffix “T” for
3000 Vrms dielectric.
UL/CUR File E44211 Approved Contact Ratings
Form A
(NO)
Form B
(NC)
Form C
NC
Load Type
Cycles
Volts
NO
General Purpose
(Inductive)
Resistive
100,000
30,000
100,000
100,000
100,000
100,000
6,000
125 or 240 VAC
277 VAC
125 or 240 VAC
30 VDC
277 VAC
240 VAC
30 A
30 A
30 A
20 A
20 A
15 A
30 A
15 A
10 A
—
—
30 A
—
20 A
—
15 A
30 A
—
10 A
—
15 A
6 A
—
3 A
—
6 A
—
3 A
Ballast
277 VAC
Pilot Duty
30,000
30,000
100,000
6,000
125 VAC
240 VAC
125 or 277 VAC
125 VAC
240 VAC
125 VAC
125 or 277 VAC
125 VAC
800 VA
690 VA
690 VA
1 HP
2 HP
1 HP
3/4 HP
96 LRA
30 FLA
82.8 LRA
27 FLA
80 LRA
30 FLA
60 LRA
20 FLA
15 A
275 VA
275 VA
—
1/4 HP
1 HP
—
470 VA
470 VA
690 VA
1 HP
2 HP
1 HP
3/4 HP
60 LRA
20 FLA
82.8 LRA
27 FLA
60 LRA
20 FLA
60 LRA
20 FLA
15 A
275 VA
275 VA
—
1/4 HP
1 HP
—
Motor Load
6,000
30,000
100,000
30,000
—
—
Definite Purpose
(LRA-Locked Rotor)
(FLA-Full Load)
33 LRA
10 FLA
—
33 LRA
10 FLA
—
100,000
30,000
125 VAC
240 VAC
277 VAC
—
—
33 LRA
10 FLA
—
—
—
—
3 A
3 A
—
33 LRA
10 FLA
—
—
3 A
3 A
—
—
TV–3
TV–3
100,000
Tungsten
6,000
6,000
6,000
6,000
25,000
25,000
125 VAC
240 VAC
120 VAC
240 VAC
120 VAC
120 VAC
5 A
—
—
TV–5
—
5 A
—
—
TV–5
—
TV–5
TV–3
TV–3
Note: See AZ2100 Data Sheet for more complete UL and CUR approved contact ratings.
10/12/00W