AT27C040
9. AC Characteristics for Read Operation
AT27C040
-70
-90
Symbol
Parameter
Condition
Min
Max
Min
Max
Units
CE = OE
= VIL
(1)
tACC
Address to Output Delay
70
90
ns
(1)
tCE
CE to Output Delay
OE to Output Delay
OE = VIL
CE = VIL
70
30
20
90
35
20
ns
ns
ns
(1)
tOE
(1)
tDF
OE or CE High to Output Float, Whichever Occurred First
Output Hold from Address, CE or OE, Whichever Occurred
First
tOH
0
0
ns
Note:
1. See AC Waveforms for Read Operation
10. AC Waveforms for Read Operation(1)
Notes: 1. Timing measurement references are 0.8V and 2.0V. Input AC drive levels are 0.45V and 2.4V, unless otherwise specified.
2. OE may be delayed up to tCE - tOE after the falling edge of CE without impact on tCE
3. OE may be delayed up to tACC - tOE after the address is valid without impact on tACC
.
.
4. This parameter is only sampled and is not 100% tested.
5. Output float is defined as the point when data is no longer driven.
5
0189H–EPROM–12/07