150W 2” x 4” Open Frame Switching Power Supplies
ASL150 series
INPUT SPECIFICATIONS
GENERAL SPECIFICATIONS
Input Voltage Range (AC / DC) 90-264 / 170-370
I/P-O/P Isolation
3000VAC for 1 Minute
1500VAC for 1 Minute
100VDC for 1 Minute
500VAC for 1 Minute
Input Current
<2.5A @ 100VAC
No Damage @ 230VAC Cold Start
47-63Hz
I/P-Ground Isolation
O/P-O/P Isolation
O/P-Ground Isolation
Inrush Current
Input Frequency
Power Factor (90VAC)
Harmonic Input Current
Input Fuse
0.98%
Meets EN61000-3-2
3A Internal Line & Neutral
80VAC Auto Recover
<275uA
ENVIRONMENTAL SPECIFICATIONS
Under Voltage Lockout
Leakage Current (120V I/P)
Oper. Temperature
-20 to +50°C FL Derate Linearly to
50% Load at 70°C *
Cooling
200LFM >100W O/P Power
8-90% Non Cond (95% Non-Oper.)
-40 to +80°C *
Relative Humidity
Storage Temperature
Operating Altitude
OUTPUT SPECIFICATIONS
Setpoint Accuracy
Overshoot during Power-on
Voltage Adjust
+/-1% Main Output V1
Out of regulation 50mS, max.
5% Main Output V1
5000 ft Above Sea Level
Derate to 40°C ambient @ 10,000 ft
Convection Cooled: 150,000Hrs
Air Flow (200 CFM): 300,000 Hrs
EN55024
MTBF
Load Regulation
+/-1% V1; +/-20% V2
+/-0.1% 90-264VAC
Line Regulation
EMC / CE Mark Requirements
Voltage Fluctuation
ESD
Cross Regulation
+/-1% V1; +/-15% V2
EN61000-3-3
Transient Response
(50% Load Change)
Start Up (HL; FL)
Rise / Hold Up Time
Temperature Coefficient
15KV Air, 8KV Contact
10% Recover within 1mS
500mS
Radiated Field
3V/m, 80-1000MHz 80% Modulation
at distance of 3M
20mS / 16mS
+/-0.25mV/°C
EFT
±2kV on AC power port for 1 minute;
±1kV on signal/ctrl lines
Ripple/Noise: 20Mhz BW, resistive load, with 22uF (tantalum) and
0.47uF (ceramic) parallel capacitors at POL
1% of Output (42% 12V aux.)
Surge
±1kV line to line/±2kV line to earth
on AC power port; ±0.5kV for outdoor
cables
Over-voltage Protection
Over Current Protection
130% max.
Conducted RF
3V; 0.15-80MHz 80% Modulation
>95% dip, 0.5 period; 30% dip, 25
periods; >95% reduction, 250 periods
EN60950, IEC60950, UL/cUL 60950
130% max. Auto Recover*
Voltage Variations
Short Circuit and Over Temp Protection
Auto Recovery *
Safety Standards (PENDING)
* These are stress ratings. Exposure of the devices to any of these conditions
may adversely affect long term reliability. Proper operation under conditions
other than the standard operating conditions is neither warranteed nor implied.
Astrodyne products are not authorized or warranteed for use
as critical components in life support systems, equipment used
in hazardous environments, nuclear controls systems, or other
mission-critical applications.
All specifications are typical at nominal input, full load, and 25DegC unless
otherwise noted