5 Absolute Maximum Ratings
Stresses beyond those listed in Table 2 may cause permanent damage to the device. These are stress ratings only, and functional operation of
the device at these or any other conditions beyond those indicated in Electrical Characteristics on page 4 is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect device reliability.
Table 2. Absolute Maximum Ratings
Parameter
Electrical Parameters
Min
Max
Units
Comments
VIN, VOUT, EN, LBI, LBO to GND
LX, REF to GND
-0.3
-0.3
-100
+5
VOUT + 0.3
100
V
V
Input Current (latch-up immunity)
mA
Norm: JEDEC 78
Electrostatic Discharge
Electrostatic Discharge HBM
Temperature Ranges and Storage Conditions
Thermal Resistance θJA
±2
kV
Norm: MIL 883 E method 3015
58
ºC/W
ºC
Junction Temperature
+125
+125
Storage Temperature Range
-55
ºC
The reflow peak soldering temperature (body
temperature) specified is in accordance with IPC/
JEDEC J-STD-020“Moisture/Reflow Sensitivity
Classification for Non-Hermetic Solid State Surface
Mount Devices”.
Package Body Temperature
+260
85
ºC
%
The lead finish for Pb-free leaded packages is matte
tin (100% Sn).
Humidity non-condensing
Moisture Sensitive Level
5
1
Represents a maximum floor life time of unlimited
www.austriamicrosystems.com/DC-DC_Step-Up/AS1310
Revision 1.8
3 - 19