GU SOP 1 Form A High Capacity Voltage-sensitive (AQY212FG2S)
4. Turn off time vs. ambient temperature
characteristics
5. Turn on voltage vs. ambient temperature
characteristics
6. Turn off voltage vs. ambient temperature
characteristics
Input voltage: 5V; Load voltage: 10V (DC);
Continuous load current: 100mA (DC)
Load voltage: 10V (DC);
Continuous load current: 100mA (DC)
Load voltage: 10V (DC);
Continuous load current: 100mA (DC)
0.5
4
4
3
0.4
0.3
0.2
3
2
1
2
1
0.1
0
0
0
-40 -20
0
20
40
60
8085
-40 -20
0
20
40
60
8085
-40 -20
0
20
40
60
8085
Ambient temperature, °C
Ambient temperature, °C
Ambient temperature, °C
7. Input current vs. ambient temperature
characteristics
Input voltage: 5V
8. Current vs. voltage characteristics of output
at MOS portion
Measured portion: between terminals 3 and 4
9. Input current vs. input voltage characteristics
Ambient temperature: 25°C 77°F
(Recommended input voltage: 5 0.5V)
Ambient temperature: 25°C 77°F
20
15
2
20
15
1
-0.6 -0.4 -0.2
10
10
5
0
0.2
Voltage, V
0.4
0.6
5
0
-1
1
-2
-40 -20
0
20
40
60
80 85
3
4
5
6
7
Ambient temperature, °C
Input voltage, V
10. Off state leakage current vs. load voltage
characteristics
11. Turn on time vs. input voltage
characteristics
12. Turn off time vs. input voltage
characteristics
Measured portion: between terminals 3 and 4
Ambient temperature: 25°C 77°F
Measured portion: between terminals 3 and 4
Load voltage: 10V (DC); Continuous load current:
100mA (DC); Ambient temperature: 25°C 77°F
Measured portion: between terminals 3 and 4
Load voltage: 10V (DC); Continuous load current:
100mA (DC); Ambient temperature: 25°C 77°F
5
4
3
2
0.5
10-4
10-6
0.4
0.3
0.2
0.1
0
10-8
10-10
10-12
1
0
0
10
20
30
40
50
60
3
4
5
6
7
3
4
5
6
7
Load voltage, V
Input voltage, V
Input voltage, V
13. Output capacitance vs. applied voltage
characteristics
14. Max. operating speed vs. load voltage-load
current characteristics
Measured portion: between terminals 3 and 4
Frequency: 1 MHz, 30m Vrms;
Ambient temperature: 25°C 77°F
Input voltage: 5V
Ambient temperature: 25°C 77°F
500
400
300
200
100
0
50
duty=50%
40
30
20
10
0
0
10
20
30
40
50
60
0
25
50
75
100
Applied voltage, V
Load voltage, V × Load current, A
ASCTB131E 201208-T
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/